Cleaning - CASO DESIGN DryAged Master 125 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 94
Interior and exterior walls
Clean the interior and exterior walls with lukewarm water and a little washing-up liquid.
Never use cleaning or chemical solvents containing sand or acid.
Then wipe the device thoroughly with a soft cloth.
Switch on the UV light for 24 hours after each ripening process.
Housing
Use a glass cleaner to clean the glass surfaces and a commercially available stainless
steel cleaner for stainless steel surfaces
Then wipe the device thoroughly with a soft cloth.
Container for condensed water (K)
Check container for the condensed water
regularly. It is located on the rear right of
the device. If necessary, remove the
condensed water with a sponge.
Manual defrosting
Defrost the device after each ageing
process.
Turn off the power but do not unplug the
power plug. Let the device then defrost manually. Pay attention to the container for
condensed water(K) and remove the condensed water during the defrosting.

18.2 Cleaning

2a H2O-reservoir
2b Holder of reservoir
2c drip tray of reservoir
H2O-reservoir
Remove holder of reservoir with drip tray
from the device. Remove the H2O-
reservoir. Release the drip tray by
pressing at the bottom side of the holder
and then pull it out. Clean the holder and
drip tray with lukewarm water and a little
washing-up liquid and then dry them.
Replace the H2O reservoir every 3 months
after use.
You can order replacement H2O
reservoirs from us, item number 693.
45

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

690

Tabla de contenido