Descargar Imprimir esta página

Fricosmos 040402 Guia De Inicio Rapido página 3

Esterilizador de cuchillos mediante agua caliente

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Read the instructions before connecting the device and store them in a safe place for refe-
rence.
INSTALATION
Before installing , make sure the device has not suffered any damage in transit.
This device is not suitable for outdoor installation.
Select the ideal location for the unit.
Do not attach the device to mobile elements such as doors, windows, etc ...
Drill 2 holes in the wall with a gap of 240 mm. between them.
Fill in the sterilizer with water up to its highest level. Make sure the drain valve in the bottom right is closed
and the drain plug is closed. Next open the upper left valve until the water reach the top level.
Connect the device to the current supply 220 -240 V (50 /60 Hz)
USE
The sterilization process must be done before using knives.
Make sure the water level is in the upper level. If the water does not reach this level, open the upper left valve
until the water reach this level.Do not forget to keep it closed.
Press on button. The power on indicator shows that it is working.
When the water is at 82 º C for 90 minutes , insert the knife clean (cleaned with water and mild soap) and dry
in the upper knife holder. This action will extend the life both of the device and the knives.
Do not turn on the power if the water is below the lower edge. This action could provoke irreversible dama-
ges.
Keep the knives in hot water for 60 minutes.
After this time, turn off the device and remove the knives.
Turn off and unplug the device whenever is not in use .
Change the water weekly. This must be done when the sterilizer is not hot by removing the drain plug and
opening the drain valve at the bottom right.
CLEANING
Clean the device regularly. Before any repairing, maintenance or cleaning work, the device must be discon-
nected from the electrical mains.
• Use only mild soap and water to clean.
• Wipe with a soft cloth.
• Rinse with a damp cloth.
• Dry with a soft cloth. The unit must be completely dry before being connected to the electrical mains.
• Do not use acids or harsh detergents or scrub with scouring pads, spatulas, knives or sharp objects.
Before any repairing, maintenance or cleaning work, the device must be disconnected from the electrical
mains.
• Turn off and unplug the machine from the electrical current when not in use .
• Use only spare parts Fricosmos .
• Only staff Fricosmos or an approved electrician can handle the device.
• Follow the cleaning instructions of this installation manual.
• Knives must be inserted clean and dry.
• Change the water weekly. This must be done when the sterilizer is not hot by removing the drain plug and
opening the drain valve at the right bottom.
The device must be only connected to an electrical installation with earth .
Not suitable for outdoor. This device is specifi cally for indoor use.
This device must be repaired only by Fricosmos staff or an approved electrician.
Before any repairing, maintenance or cleaning work, the device must be disconnected from the electrical
mains.
Use only Fricosmos spare parts when repairing this article.
It is not intended for persons ( including children) physically, mentally or sensory disabled, or with lack of
experience or knowledge, unless a person in charge of security provides the proper instructions.
Fricosmos will not be responsible for unauthorized handling of this product.
Do not turn on the power if the water is below the lower edge. It could provoke irreversible damages.
Do not remove the protective casing of the device
This device must be repaired only by Fricosmos staff or an approved electrician
449008 Sphere valve M - F 3/8 inches.
449040 Electrical Resistance 1000W with switch.
449006 Stainless steel mesh fl exible F ­ F 3/8 inch length 400 mm
449026 Chromed plug 3/8 inches.
041004 Plated knife holder 450x90x30 mm
449028 Monitoring indicator
The device is guaranteed for two years. Handling or misuse of equipment eliminates the warranty. Failure of
some point of this manual eliminates the guarantee.
Graphic sterilizing.
MAINTENANCE
SAFETY
SPARE PARTS
GARANTÍA - WARRANTY - GARANTIE - GARANTIE
Do not touch the metal parts of the sterilizer while it is on
This device is specifi cally for indoor use.

Publicidad