Faber INCA SMART INSM28GR240 Instrucciones De Instalación página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PLAN YOUR DUCTWORK
WARNING
!
When building a custom hood, always
follow all applicable codes and
standards.
WARNING
!
The Inca Smart can be used in
When building a custom hood,
standard 24" or 30" or 36" wide
always follow all applicable
cabinetry or with custom hoods
codes and standards.
30" wide and up.
The Inca Smart can be used in
standard 30" or 36" wide cabinetry
For custom/wood hoods,
or with custom hoods 30" wide
choose either YOUR OWN
and up.
custom liner or our Standard
For custom/wood hoods, choose
Liner designed for 24"and 30"
either YOUR OWN custom liner or
and 36" wide installations.
our Standard Liner designed for 30"
Liners create a perfectly -
and 36" wide installations. Liners
create a perfectly-sealed, non-
sealed, non-combustible
combustible finish for the underside
finish for the underside of your
of your custom/wood hood.
custom/wood hood.
The Standard Liners are made
up of two sections: a larger, rear
The Standard Liners are made
section (pre-cut out for insertion of
the Inca Smart) and a front section
up of two sections: a larger,
for a total adjustable depth between
rear section (pre-cut out for
16" and 17
.
7/8"
insertion of the Inca Smart)
!!! IMPORTANT NOTE: DO NOT
and a front section for a total
REMOVE THE ADDITIONAL
P E R F O R AT E D
S E C T I O N
adjustable depth between 16"
A R O U N D T H E P R E - C U T-
and 17 7/8".
O U T W H E N I N S TA L L I N G
THE STANDARD LINER WITH
THE INCA SMART MODEL.
!!! IMPORTANT NOTE: DO NOT
THIS PERFORATION IS ONLY
REMOVE THE ADDITIONAL
REMOVED FOR USE WITH THE
INCA HC SS MODEL.
PERFORATED SECTION AROUND
THE PRE-CUT-OUT WHEN
Consider the shape, size, and
INSTALLING THE STANDARD
weight of the Inca Smart and Liner
to determine the configuration
LINER WITH THE INCA SMART
of the custom/wood hood. See
MODEL.
RANGEHOOD DIMENSIONS AND
LINER DIMENSIONS on Page 4.
Consider the shape, size,
and weight of the Inca Smart
and Liner to determine the
configuration of the custom/
wood hood.
See RANGEHOOD DIMENSIONS
AND LINER DIMENSIONS.
10
• 2 Conduit Connectors
• Power Supply Cable
• Scews for Field Wiring Box
• 1 Wall or Roof Cap
• All Metal Ductwork
FOR INSTALLATION WITH LINERS
The Inca Smart requires 5" round ductwork. To ensure that the blower performs to its
highest possible capacity, ductwork should be as short and straight as possilbe.
Make your ductrun as straight and short as possible. The ductrun should not exceed 25
equivalent feet if ducted with the required minimum of 5" round duct. Count 45º angles
as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is a minimum
of 24" of straight duct between elbows if more than one is used. Do not install two
elbows together. If you must elbow right away, do it as far away from the hood's
exhaust opening as possible.
CUSTOM/WOODH
CUSTOM/WOOD
HOOD
HOOD
INCA SMART
INCA SMART
1. The custom/wood hood must have a sturdy base (3/4" plywood recommended) to accomodate
the cut-out for the Inca Smart. The base must be recessed to accomodate the height of the
Liner (see LINER DIMENSIONS on Page 4). The Liner attaches to the bottom of the base
using screws appropriate for the size and material of your custom/wood hood. The Inca Smart
inserts into the cut-out in the Liner and base.
2. Position the rear section of the Liner so that it abuts the back edge of your custom/wood
1. The custom/wood hood must have a sturdy base (3/4" plywood
hood. Using a pen, trace the outline of the pre-cut out. Remove the Liner and proceed to MAKE
YOUR CUT-OUTS on Page 6. Install both sections of the Liner and proceed to INSTALL THE
recommended) to accomodate the cut-out for the Inca Smart. The base
RANGEHOOD on Page 6.
must be recessed to accomodate the height of the Liner (see LINER
DIMENSIONS). The Liner attaches to the bottom of the base using
screws appropriate for the size and material of your custom/wood hood.
The Inca Smart inserts into the cut-out in the Liner and base.
2. Position the rear section of the Liner so that it abuts the back edge of
your custom/wood hood. Using a pen, trace the outline of the pre-cut out.
Remove the Liner and proceed to MAKE YOUR CUT-OUTS.
Install both sections of the Liner and proceed to INSTALL THE
RANGEHOOD.
perimeter around the Inca Smart. Depth adjustable
from 16" - 17
Standard Liner 30 Stainless - part #
Standard Liner 36 Stainless - part #
FOR INSTALLATIONS WITH LINERS
.
7/8"
LINE30ST
LINE36ST
Version 09/14 - Page 5