A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-de-
lay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance
with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near
the field wiring compartment.
!
• Electrical ground is required on this Range Hood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO
NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or
grounding circuit could result in electrical shock.
• Check with a qualified electrician if you are in doubt as to whether the Range Hood is
properly grounded.
• Failure to follow electrical requirements may result in a fire.
State of California Proposition 65 Warning (US only)
WARNING
This product contains chemicals known to the State of California to cause cancer and birth
defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
4
ELECTRICAL REQUIREMENTS