1
Introduction to the instructions and warnings
This manual is intended only to qualified technician
for installation.
No information contained in this document may be
considered of interest to the end user.
This manual refers to R92/LED24 and R92/LED230
led flashing lights and must not be used for different
products.
RISK OF
WARNING
ELECTRIC SHOCK
Read the instructions carefully before performing
the installation.
To avoid the risk of electric shock and personal
injury, before working with the device, disconnect
the power supply.
Installation should only be performed by qualified
personnel in accordance with current laws.
Make the connections with appropriate cables with
the current and voltage required and respect the
features of the product.
2

Product description

The flashing lights R92/LED24 and R92/LED230
are signal lights, made by LED, to be connected to
engine control units for the automation of gates.
The difference between the two versions is the
supply voltage, R92/LED24 is powered by 24Vac/dc,
while R92/LED230 is powered by 230Vac.
Both models come standard with the flash function
enabled, when the flashing light is powered the light
is switched on and off once per second. You can turn
off the blinking cutting the bridge (J1, see picture 1)
in this way the light is on all the time in which power
is applied. If you choose this option, the control unit
must be configured to perform the switching on and
5

Technical features

POWER SUPPLY
MAX POWER ABSORPTION
WORKING TEMPERATURE
PROTECTION GRADE
PRODUCT SIZE
off of the light (parameter 78). In this way you can
achieve different flashing modes for opening and
closing or to report error conditions.
4
Installation
Fix with care the base of the flashing light to a flat, solid
and vibration-free surface, as shown in picture 2.
Make sure that the cable entry is sealed.
Make the connections to the control unit, the
scheme is shown in pictures 3 and 4. If you are using
the R92/LED230 connected to a control unit with
an output voltage free (control units series H70)
protect the device using a fuse 500mA delayed.
Connect the possible antenna (R91/AN1/LR1).
Place the cover and secure it with the supplied
screws and place the cover ring, see picture 2.
5
Disposal
The product must be always uninstall by the technical
and qualified staff, using appropriate processes for the
correct removal of the product.
This product is made of different materials, some
of them could be recycled others must be disposed
through recycling or disposal systems established by
local regulations for this product.
It is forbidden to dispose the product into the house
garbage. Make the "separate collection" for disposal
according to the methods established by local
regulations; otherwise return the product to the seller
when you buy the new equivalent product.
Local regulations may provide for heavy penalties for
illegal disposal of this product.
Caution: some parts of the product may
contain pollutants and hazardous, if
thrown they may cause dangerous effects
to the environment and to the human
health.
R92/LED24
24V ac/dc ± 10%
13W
-20°C ÷ +55°C
IP44
dimension in mm.Ø128 h.131(without antenna) Weight: 240g
R92/LED230
230Vac ± 10% 50Hz
10W
EN
3