Page 16
ENGLISH
Section 4. Operation
4.1
K-1100, LEV110CK/2G, and LX2
The controllers for the K-1100 and LEV110CK/2G (See
Figure 22) and the LX2 (See Figure 23) each have three
(3) lights. Refer to the figures and Table 1.
Power Light
Sensor Light Filling Light
Power
Figure 22. K-1100 and LEV110CK/2G Controller
Lights
LED
Power
Turn Power ON
Sensor
Detect Low Water Yellow
Filling for
K-1100 and LX2
Safety Lockout
Filling for
LEV110CK/2G
Safety Lockout
Table 1. LED Indicators for K-1100, LX2, and LEV110CK/2G
Jandy Levolor
®
Models K-1100, LX2, K-2300, and LEV110CK/2G
Sensor
Filling
Function
Color
Green
Filling Pool
Green
Red
Filling Pool
Green
Red
Electronic Water Leveler
Power Light
Figure 23. LX2 Controller Lights
The Power light turns green when the unit is
powered on. The Sensor light turns yellow when water
is not touching the sensor tips.
The Filling light turns green 20 seconds after the sensor
light illuminates, indicating that the valve is operational
and filling. The Filling light turns off when the pool is
filled.
The Filling light turns red when the unit enters Fill
Safety Lockout Mode. This happens if it takes longer
to fill the pool than the time period allotted (20, 40, or
60 minutes). For more information, see Section 4.3, Fill
Safety Lockout Mode.
NOTE The time period allotted for the LEV110CK/2G
to fill is one (1), two (2), or three (3) hours.
See Table 1.
Operating
Delay to Turn
Mode
Function ON
Power is
ON
Water is
Low
20 Seconds after
Fill Valve is
Sensor Light
ON
Turns ON
Fill Valve is
20, 40 or 60 Minutes
OFF
20 Seconds after
Fill Valve is
Sensor Light
ON
Turns ON
Fill Valve is
1, 2, or 3 Hours
OFF
|
Installation and Operation Manual
Sensor Light
Fill Light
Delay to Turn
Function OFF
None
None
None
None
20 Seconds after
Sensor Light
Turns OFF
24 Hours
20 Seconds after
Sensor Light
Turns OFF
24 Hours