Silvercrest SLE 200 A1 Instrucciones De Uso página 77

Ocultar thumbs Ver también para SLE 200 A1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Do not permanently install the appliance. Position the ap-
pliance so that its side panels have a clearance of at least
20 cm from walls or other objects and ensure a clearance
of at least 50 cm from the front, rear and top panels of the
appliance in order to ensure good air circulation. Take care
not to obstruct the air inlet and outlet opening.
The appliance may only be operated in rooms with an ambi-
ent temperature of 5°C to 32°C.
Use the appliance only in rooms up to 16 m².
The appliance must be installed, operated and stored in a
room with a floor area greater than 4 m
If the appliance is operated in unventilated areas, these
must be designed in such a way that the refrigerant cannot
accumulate anywhere in the event of refrigerant leakage.
Otherwise, a combustible mixture may be formed.
The appliance may only be stored in rooms without perma-
nent sources of ignition (e.g. open flames, a switched-on gas
appliance or an electric heater).
The appliance must be stored in a way that does not dam-
age it.
Clean the air filter before it gets too badly contaminated.
While draining via a hose, ensure that it does not become
blocked and that the open end of the hose is positioned at a
lower level than the outlet aperture. The end of the hose must
be positioned above a drain.
Operate the appliance only together with the water tank or
with the hose installed.
74 
GB │ MT
2
.
SLE 200 A1

Publicidad

Tabla de contenido
loading

Tabla de contenido