Cap
Handle
Bonnet
Stop
Tab
Mounting
Nut
4. Adjust the Maximum Temperature
NOTE
Prior to adjustment, make sure the handle is in the
:
maximum hot position.
- Remove the cap, handle and bonnet. Turn on the water to the
maximum hot water temperature by pushing the valve stem up, and
turning it fully clockwise.
- Use a pencil or marker to mark the current position of the
temperature stop tab (top edge) on the mounting nut. Lift both the
indexer and the top disc just enough to clear the splines and to allow
rotation.
NOTE
Each indexer notch is an average 9.5_F (5.3_C) change in
:
temperature.
- Turn the indexer, top disc, and valve stem counterclockwise until
you achieve the desired temperature. Then re install the indexer and
top disc to the valve. Make sure the top disc is snapped fully into the
indexer.
- Turn off the water, and re install the bonnet, cap and handle.
Kohler Co.
Screw
Valve
Stem
Top Disc
Splines
5
A
1011034-2-