Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

::
.com
bathroomsource
SOLITAIRE ULTRA-SILENT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
TYPICAL INSTALLATION
POWER
CABLE
DAMPER/DUCT
CONNECTOR
CEILING
JOIST
GRILLE
This unit can be installed anywhere between joists using mounting
brackets provided.
INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER.
HOMEOWNER: USE AND CARE INSTRUCTIONS ON PAGE 3.
Broan at
Call 1-800-667-8721 anywhere in the US and Canada -
MODELS
S50U, S80U, S80UE,
S110U & S110UE
4" ROUND
HOUSING
MOUNTING
BRACKET
FINISHED CEILING
::bathroomsource.com
®
FAN
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. This unit may be used over a tub or shower enclosure when
installed in a GFCI protected branch circuit. (Ceiling Installation
only)
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further information
and requirements
The unit can be
installed in a
suspended ceiling
using wire as
shown.
The unit will operate
most quietly when
located where the
shortest possible
duct run and
minimum number of
elbows will be
needed.
Plan to supply the
unit with proper line voltage and appropriate power cable.
Follow these basic steps when installing this unit:
• Nail housing to joists.
• Attach ductwork.
• Connect power cable.
• Install blower assembly.
• Fasten grille to housing.
kitchen::
is a division of
U
N
www.bathroomsource.com
.
POWER
CABLE
accessories
L
I
M
I
T
E
D

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan S50U

  • Página 1 .com bathroomsource www.bathroomsource.com Call 1-800-667-8721 anywhere in the US and Canada - MODELS S50U, S80U, S80UE, S110U & S110UE ® SOLITAIRE ULTRA-SILENT READ AND SAVE THESE INSTRUCTIONS 6. Ducted fans must always be vented to the outdoors. WARNING 7. If this unit is to be installed over a tub or shower, it must be marked...
  • Página 2 Check damper to make sure that it opens freely. flush with finished ceiling. Mark the top of keyhole on all four Tape all duct connections to make them secure and air tight. mounting brackets. kitchen:: ::bathroomsource.com Broan at is a division of accessories...
  • Página 3 .com bathroomsource www.bathroomsource.com Call 1-800-667-8721 anywhere in the US and Canada - kitchen:: ::bathroomsource.com Broan at is a division of accessories...
  • Página 4: Service Parts

    TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Página 5: Solitaire Ultrasilencio Ventilador

    .com bathroomsource www.bathroomsource.com Call 1-800-667-8721 anywhere in the US and Canada - MODELOS S50U, S80U, S80UE, S110U & S110UE ® SOLITAIRE ULTRASILENCIO VENTILADOR LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA 5. Cuando corte o taladre en una pared o techo, no dañe los cables eléctricos u otras instalaciones ocultas.
  • Página 6: Instalacion Del Ventilador (Cont)

    5. Instale ducto redondo de 102 mm y extiéndalo hacia afuera a través del techo o una tapapared. Compruebe que el registro de tiro se abre fácilmente. Cubra con cinta adhesiva todas las conexiones de ductos para hacerlas seguras y herméticas. kitchen:: ::bathroomsource.com Broan at is a division of accessories...