Before you begin - Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer – Be sure to leave these instructions with the end user.
Note to end user – Keep these instructions with your Owner's Manual for future reference.
YOUR WALL PLENUM WILL ONLY WORK IF INSTALLED CORRECTLY. MAKE SURE TO INSTALL THE
WALL PLENUM IN THE CORRECT ORIENTATION AS SHOWN IN THE ILLUSTRATIONS. For easier
installation, Grille Kit RAVAL3 should be installed at time of Wall Plenum Installation.
Parts Included
There are two parts to a Wall Plenum:
Part A - Outside Plenum
Installed so the large opening is on the bottom and the drain holes
and keyhole slots for attaching the grille are on the outside of the
building.
Part B - Inside Plenum
Installed so the large opening is on the bottom and the top and
side flanges are against the inside wall of the building.
Materials Needed (Field Supplied Parts)
• Exterior silicone caulk (recommended)
• Flashing
• Shims
• Header Material/Wall Studs
• 1" - 3" Screws to attach the plenum assembly to the wall
studs.
• Grille Kit RAVAL3 (sold separately)
Installation Overview
Properly sized header is
required for structural
support. Proper caulking
and flashing are required
RAVDPLAT
Unit
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Installation Instructions
for your new
RAVWPT15
Wall Plenum
Part B Inside
Wall Plenum
Large
opening
Exterior/
Outside Wall
Part B Inside
Wall Plenum
Large
opening
Part A outside
Wall Plenum
NOTE: The plenum has a
wax cardboard weather
cover. Do not remove
this cover until ready
to install the grille
(RAVAL3)
Part A Outside
Wall Plenum
31-5000506 Rev. 0 08-20 GEA

Publicidad

Tabla de contenido
loading

Resumen de contenidos para GE RAVWPT15

  • Página 1 (RAVAL3) Part A Outside Wall Plenum Exterior/ Outside Wall Part B Inside Wall Plenum RAVDPLAT Unit GE is a trademark of the General Electric Company. Manufactured under trademark license. 31-5000506 Rev. 0 08-20 GEA...
  • Página 2: Installation Instructions

    Installation Instructions STEP 1 Outside Wall Plenum Opening Ensure the outside wall plenum opening is properly framed and square per the diagram shown below. IMPORTANT: The wall plenum is not designed to carry structural loads. A proper header must be built into the rough opening and a proper lintel must be installed to support brick or other masonry materials.
  • Página 3 Installation Instructions STEP 3 Install Grille Kit RAVAL3 (not included) on the Outside Plenum NOTE: The Grille Kit RAVAL3 is best installed onto the Side View Outside Plenum (Part A) prior to the wall plenum being installed into the building. Grille installation is easier at this point and will help keep the wall plenum square during installation.
  • Página 4 Installation Instructions STEP 4 Plenum Installation (cont.) Secure plenum using the field supplied screws through If additional screws are used to secure the inside of the the four provided slots in the plenum front face. wall plenum to the rough opening framing, only drive screws through the vertical sides of the wall plenum.
  • Página 5: Liste Des Pièces

    Extérieur/ Mur extérieur Exterior/ Outside Wall Partie B Plénum mural Part B Inside intérieur Wall Plenum RAVDPLAT Appareil Unit GE est une marque de commerce de General Electric Company. Fabriqué sous licence d’utilisation de marque. 31-5000506 Rev. 0 08-20 GEA...
  • Página 6 Instructions d’installation ÉTAPE 1 Ouverture de plénum de mur extérieur Assurez-vous que la structure de l’ouverture de plénum de mur extérieur est adéquate et à l’équerre, comme montré dans le schéma ci-dessous. IMPORTANT: Le plénum de mur n’est pas conçu pour supporter une charge structurelle.
  • Página 7 Instructions d’installation ÉTAPE 3 Installer l’ensemble de grille RAVAL3 (non compris) sur le plénum extérieur REMARQUE: il est préférable d’installer l’ensemble de grille Vue latérale RAVAL3 sur le plénum extérieur (Partie A) avant d’installer le plénum mural sur le bâtiment. L’installation de la grille est plus facile à...
  • Página 8 Instructions d’installation ÉTAPE 4 (suite) Installation du plénum Fixez fermement le plénum à l’aide des vis fournies sur Si vous devez utiliser d’autres vis pour fixer fermement place en les insérant dans les quatre fentes prévues sur la l’intérieur du plénum mural à l’ouverture brute de la face du plénum.
  • Página 9: Piezas Incluidas

    Outside Wall Pieza B Part B Inside Plénum de la Wall Plenum Pared Interna RAVDPLAT Unidad Unit GE Appliances es una marca registrada de la Empresa General Electric. Fabricado bajo licencia de la marca registrada. 31-5000506 Rev. 0 08-20 GEA...
  • Página 10: Pieza A Afuera Del Plénum De Pared

    Instrucciones de Instalación PASO 1 Pieza A afuera del Plénum de Pared Asegúrese de que la abertura exterior del plénum de pared esté correctamente enmarcada y en ángulo recto de acuerdo con el diagrama que figura a continuación. IMPORTANTE: El plénum de pared no fue diseñado para transportar cargas estructurales.
  • Página 11: Instale El Kit De Rejilla Raval3 (No Incluido) En El Plénum Externo

    Instrucciones de Instalación PASO 3 Instale el Kit de Rejilla RAVAL3 (no incluido) en el Plénum Externo NOTA: La instalación del Kit de Rejilla RAVAL3 es más conveniente en el Plénum Externo (Pieza A), antes de la Vista Lateral instalación del plénum de pared en el edificio. La instalación de la rejilla es más fácil en este punto, y ayudará...
  • Página 12 Instrucciones de Instalación PASO 4 (cont.) Instalación del Plénum: Asegure el plénum insertando los tornillos suministrados a Si se usan tornillos adicionales para asegurar la parte través de las cuatro ranuras provistas sobre la cara frontal interior del plénum de pared sobre el marco de la abertura del plénum.

Tabla de contenido