When Servicing
• Turn the power OFF at the main power box (mains)
before opening the unit to check or repair electrical parts
and wiring.
• Keep your fi ngers and clothing away from any moving
parts.
• Clean up the site after you fi nish, remembering to check
that no metal scraps or bits of wiring have been left inside
the unit being serviced.
Gas Supply Pressure
Pressure(mbar)
Gas Supply
Gas Supply
Min.
Max.
Normal
G20, G25
17
20
25
(Natural Gas)
SAFETY PRECAUTIONS
• Be sure to arrange installation from the dealer where the system was purchased or using a professional installer.
If you attempt to perform the work yourself, and do so incorrectly, there is danger of poisoning caused by exhaust
gases entering the building, as well as danger of water leakage, electric shock and fi re.
• Installation work must be performed correctly, in accordance with the instructions listed here. Hazards from
incorrect installation include dangerous exhaust gas buildup, water leakage, electric shock and fi re.
• Check the type of engine fuel used. If the wrong type of gas is used, the engine can suffer combustion problems,
and there is danger of poisoning caused by exhaust gases.
• Ventilate the area in case refrigerant gas leaks during installation work. If refrigerant gas comes into contact with
frame during the tube brazing process, toxic gas will be produced.
• When installation work is completed, check that there is no refrigerant gas leakage.
If refrigerant gas leaks into the room and contacts the frame of a fan heater, stove, burner, or other device, toxic
gases will be produced.
• Never use refrigerants other than the one specifi ed (written on label on the unit).
• When installing or moving the A/C unit, do not allow refrigerants other than the one specifi ed (written on the
label on the unit) or air to enter the unit's refrigeration cycle.
• Always use nitrogen for the airtightness test. (Do not use oxygen-based gases.)
• When handling refrigerant gas, do not come in contact with the gas directly. Doing so may result in frostbite.
Check that all provided parts are present.
Provided documents:
• Remote power switch label
• Label showing the actual length of refrigerant tubing and amount of refrigerant charge
• Seal labels
• This manual ("Procedures and Technical Points for System Installation")
• "Procedures and Technical Points for Test Run"
• "Procedures and Technical Points for Electrical Wiring Work (Outdoors)"
Pressure(mbar)
Min.
Max.
Normal
G31
25
37
45
(LPG)
GB - 22
Others
• Ventilate any enclosed areas when installing or testing
the refrigeration system. Escaped refrigerant gas, on
contact with fi re or heat, can produce dangerously toxic
gas.
• Confi rm upon completing installation that no refrigerant
gas is leaking. If escaped gas comes in contact with a
stove, gas water heater, electric room heater or other
heat source, it can produce dangerously toxic gas.