CONVERTIDOR CC/CC 500W para aplicación Industrial y Ferroviaria
500W DC/DC CONVERTERS for Industrial and Railway application
Ejemplo de pedido: CRS-500-6458-BO 48/24V v. industrial + ORing
www.premium.es
NP-9135
NP-9222
2601-395
START-UP
Perform connection according to the figure. Use of remote sensing is not
absolutely necessary, but if this is required, use of a co-axial or a
twisted-pair cable is recommended.
WARNING: If the load is connected to the tabs of remote sensing (+/-S)
and the connection from the output to this load is missing the remote
sensing function could make unusable due to the acting of the internal
fuse of protection.
If power levels close to the maximum output are required, make sure the
assembly enhances cooling by natural convection and the unit is placed
in vertical position.
If several converters need to be connected in parallel, do the
following:
• Set the output voltage for all converters featuring a mutual difference
as small as possible.
• Join the load outputs by using cables with a cross-section no greater
than the one required and of equal length.
• Do not use remote sensing.
For safety reasons, the following requirements must be complied
with:
• Provide the equipment with some kind of protective enclosure that
complies with the electrical safety directives in effect within the country
where the equipment is installed.
• Only replace the fuse with another fuse of the same rating and type,
and only after disconnecting the converter from DC power.
OPCIONES
Versión industrial básica
Versión ferroviaria básica
• Tiempo de mantenimiento de 10ms (Nota-1)
• Protección activa contra inversión de
polaridad de entrada
• Limitación activa de corriente de arranque:
I(arranque) < 3·I(entrada nom.)
Oring FET para redundancia
Caja sin escuadras de fijación para subrack de
6U o carril DIN
OPTIONS
Industrial basic version
Railway basic version
• Hold up time 10ms (Note-1)
• Active protection against input reverse polarity
• Active inrush current limiter:
I(inrush): < 3·I(input nominal)
Oring FET for redundancy
Case without mounting brackets for 6U subrack
fitting or DIN rail
ACCESORIOS
CLIP CARRIL DIN
Pletinas guía para subrack
Conector hembra de señales
ACCESSORIES
DIN RAIL CLIP
Subrack guiding plates
Signals female connector
Nota-1
Tiempo de mantenimiento: 10ms a 500W y Vin nom para todos los
modelos excepto para 6455 y 6456 a 440W y Vin nom
Note-1
Hold up time: 10ms at 500W and Vin nom for all the models except 6455
and 6556 at 440W and Vin nom.
/ Ordering example: CRS-500-6458-BO 48/24V Industrial v. + ORing
3/5
CÓDIGO PEDIDO
CRS-500-64XX-B
CRS-500-64XX-T
CRS-500-64XX-H
CRS-500-64XX-O
CRS-500-64XX-P
ORDERING CODE
CRS-500-64XX-B
CRS-500-64XX-T
CRS-500-64XX-H
CRS-500-64XX-O
CRS-500-64XX-P
CÓDIGO PEDIDO
2 x NP-9135
1 x NP-9222
2601-395
ORDERING CODE
2 x NP-9135
1 x NP-9222
2601-395
06-11-2013
9502-126-11
CRS-500
CA-439-11

Publicidad

loading

Este manual también es adecuado para:

Crs-500-6455Crs-500-6456Crs-500-6467Crs-500-6468Crs-500-6458Crs-500-6459 ... Mostrar todo