Guideline value table for the presetting of the heating system with Thermix
Boiler circuit
Preliminary
preliminary
heat
heat
temperature
temperature
mixed
unmixed
heating circuit
heating circuit
(°C)
(°C)
Achievement mixed heating circle (kW)
25
30
35
65
40
45
50
All data are guideline values; depending on the system, deviations can occur = Thermix cannot be used. Guide-value tables for deviating
supply water temperatures, spreads and pressure losses can be supplied on request.
21
Spread for
Pressure
pump setting of
mixed
loss mixed
Thermixpumpe
heating
heating
circuit
circuit
(K)
(bar)
5
0.10
3
3
0.15
3
0.20
3
0.10
1
5
0.15
2
0.20
2
0.10
1
5
0.15
2
0.20
2
0.10
1
7
0.15
1
0.20
2
0.10
1
5
0.15
2
0.20
2
0.10
1
7
0.15
1
0.20
2
0.10
1
7
0.15
1
0.20
2
0.10
1
10
0.15
1
0.20
1
0.10
1
10
0.15
1
0.20
1
0.10
1
15
0.15
1
0.20
1
0.10
1
15
0.15
1
0.20
1
0.10
1
20
0.15
1
0.20
1
necessary volumetric flow of
the boiler circuit
(I/h)
10
15
20
5
10
-
-
-
102
-
-
-
-
102
-
-
-
-
102
-
3
-
-
97
195
3
-
-
97
195
-
-
-
97
-
3
-
-
110
219
3
-
-
110
219
-
-
-
110
-
2
3
-
104
209
313
3
-
-
104
209
3
-
-
104
209
3
-
-
125
251
3
-
-
125
251
-
-
-
125
-
2
3
-
119
237
356
3
-
-
119
237
3
-
-
119
237
2
3
-
137
274
411
3
-
-
137
274
3
-
-
137
274
1
3
3
125
251
376
2
3
3
125
251
376
2
3
-
125
251
376
1
3
3
146
292
438
2
3
3
146
292
438
2
3
-
146
292
438
1
1
2
125
251
376
1
2
2
125
251
376
1
2
3
125
251
376
1
1
2
146
292
438
1
2
2
146
292
438
1
2
3
146
292
438
1
1
1
125
251
376
1
1
2
125
251
376
1
2
2
125
251
376
necessary pressure diffe-
rence
before Thermix
(from the boiler circuit)
(bar)
15
20
5
10
15
-
-
0.01
-
-
-
-
0.01
-
-
-
-
0.01
-
-
-
-
0.01
0.02
-
-
-
0.01
0.02
-
-
-
0.01
-
-
-
-
0.01
0.02
-
-
-
0.01
0.02
-
-
-
0.01
-
-
-
0.01
0.02
0.07
-
-
0.01
0.02
-
-
-
0.01
0.02
-
-
-
0.01
0.04
-
-
-
0.01
0.04
-
-
-
0.01
-
-
-
0.01
0.03
0.09
-
-
0.01
0.03
-
-
-
0.01
0.03
-
-
0.01
0.05
0.13
-
-
0.01
0.05
-
-
-
0.01
0.05
-
501
0.01
0.04
0.11
0.21
501
0.01
0.04
0.11
0.21
-
0.01
0.04
0.11
585
0.01
0.06
0.15
0.31
585
0.01
0.06
0.15
0.31
-
0.01
0.06
0.15
501
0.01
0.04
0.11
0.21
501
0.01
0.04
0.11
0.21
501
0.01
0.04
0.11
0.21
585
0.01
0.06
0.15
0.31
585
0.01
0.06
0.15
0.31
585
0.01
0.06
0.15
0.31
501
0.01
0.04
0.11
0.21
501
0.01
0.04
0.11
0.21
501
0.01
0.04
0.11
0.21
Effiziente Energietechnik