TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
it will detect motion. When first turned on or when
switching modes, wait 1
2. Turn the SENSITIVITY (SENS) control to the mid position
and the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating
vents and air conditioners. These heat sources could
cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting daylight may
trigger the shut-off feature. Do not point other lights at the
sensor.
5 ft.
60 ft.
Maximum Range
206441-01
1
/
minute warm up period before
2
/
minutes.
1
2
SENS
MIN
MAX
Maximum
Coverage Angle
The detector is less sensitive to motion directly towards it and
more sensitive to across motion.
Motion
Least Sensitive
3. Walk through the coverage area
noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area.
4. Adjust the SENSITIVITY as
needed.Too much sensitivity may
increase false triggering.
5. Set the amount of TIME you want
the lights to stay on after motion is
detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . . . . Up to 60 feet (varies with surround-
Sensing Angle . . . . . . . . . Up to 110°
Electrical Load. . . . . . . . . Up to 500 Watts Maximum, Incan-
110°
Power Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . . . . . . TEST, AUTO and MANUAL OVER-
Time Delay . . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue products and
to change specifications at any time without incurring any
obligation to incorporate new features in products previously
sold.
3
Motion
Sensor
Most Sensitive
Aim Sensor Down
for Short Coverage
Aim Sensor Higher
for Long Coverage
ing temperature).
descent