8
Advanced settings
How to set up swing type
3
1
Push
for at least four seconds when
the air conditioner is not working.
•
, symbol, and numbers flash.
2
Select an indoor unit to be set by pushing
(left side of the button).
• Each time you push the button, unit numbers
change as follows:
Unit No.
Unit No.
Unit No.
1-1
1-2
1-3
Not
Unit No.
display
1-4
The fan of the selected unit runs and the louvers
start swinging.
3
Select a swing type by pushing TIME
buttons.
Swing setup code
Swing setup code
Swing of louvers
Standard swing
0001
(Factory default)
0002
Dual swing
0003
Cycle swing
CAUTION
Do not set the swing setup code to "0000".
(This setting may cause a failure of the louvers.)
105-EN
1
2
• Standard swing
The four louvers swing in the same direction.
• About "Dual swing"
"Dual swing" means that louvers 01 and 03 are
directed and swing in one direction, and/then louvers
02 and 04 are directed and swing in the opposite
direction.
(When louver 01 is directed downward, louver 02 is
directed horizontally.)
• About "Cycle swing"
The four louvers swing independently at respective
timings.
03
04
02
01
Drain pipe
Refrigerant pipe
4
Push
button.
5
Push
button to complete the setting.
– 53 –
How to set up louver lock (No swing)
3
4
1
Push
(right side of the button) for at
least four seconds when the air conditioner
is not working.
•
, symbol, and numbers flash.
2
Select an indoor unit to be set by pushing
(left side of the button).
• Each time you push the button, unit numbers
change as follows:
The fan of the selected unit runs and the louvers
start swinging.
Unit No.
Unit No.
Unit No.
1-1
1-2
1-3
Unit No.
1-4
3
Display the number of a louver you want to
lock on the temperature display section by
pushing TEMP.
buttons.
• The selected louver starts swinging.
4
Select the wind direction of the louver you
do not want to swing by pushing TIME
buttons.
(1)
(2)
(3)
CODE
0001
0002
0003
(4)
(5)
0004
0005
2 1
CAUTION
When (4) or (5) is selected, dew drop may occur during
cooling mode.
5
Determine the setting by pushing
button.
• When the setting has been determined,
lights up.
(To continue louver lock settings for other indoor
units, repeat from step 2. To continue louver
lock settings for other louvers on the same
indoor unit, repeat from step 3.)
6
Push
button to complete the setting.
0001-0005
(Louver lock position code)
• A louver number is displayed as F1, F2 on the
remote controller (Item Code), showing that
louver 01, 02 shown in the figure on the previous
page is selected.
NOTE
Even when louvers are locked, they move temporarily
in the following cases:
• While the air conditioner is stopping
• At the beginning of heating operation
• During defrosting operation
• When the room temperature reached the set
temperature
106-EN