34
en
Notes
NOTICE!
Installation must only be performed by authorized and specialized personnel!
Refer to Figure 1 on Page 5 for the information on the scope of delivery.
WARNING!
Live components and stripped cable! Risk of injury from electric shock. The system must be
current-free during connection work.
Functional Description
The Remote Keypad can be used to perform the same operating procedures as the control panel, enabling variable
operation of a networked system. It has the following functional elements (see Figure 1, III, Page 5):
Pos.
Designation
A
Touch screen
B
22 fixed buttons
C
11 LEDs
D
Key switch
E
Reboot button
F
6-pin DIP switch
G
3 rotary switches
Installation
Follow the mounting instructions according to the mouting variant for your application.
Before mounting the housing, remove the operating unit. This prevents the touch screen being damaged and
facilitates installing the lower mounting screws.
Mounting variants
Surface wall mounting
Flush wall mounting
Tilted installation
Wiring
Connect the shield wires to the screw terminal, see Figure 11, Page 14 (step 1).
Fasten the cables with cable ties, see Figure 11, Page 14 (step 1 to 4).
The Remote Keypad has
-
two CAN interfaces (CAN1/CAN2) to enable system networking (bus or loop topology), see Figure 14, Page 17
-
two signal inputs (IN1/IN2)
-
Ethernet, USB and RS232 interfaces
When connecting to the USB and RS232 interface, observe the maximum cable length of 3 m (see Figure 10,
Page 13).
Address Setting and Configuration
Assign a unique physical address to each Panel Controller and Remote Keypad by setting the rotary switches and
write it down on the label (see Figure 13, Page 16, step 1 and 2).
For configuration, set the 6-pin DIP switch (see Figure 13, Page 16, step 3). Mark the setting on the provided label
(step 4).
On pages 17 to 25, you will find the different types of network topologies with the required DIP switch and address
settings.
F.01U.029.078 | 5.0 | 2009.11
Function
Operating the networked system through virtual buttons and variable display windows
Standard entries
Indicating the operating status
2 switch settings, freely programmable, e.g. for switching between day/night mode or
connecting/disconnecting for local alarm signaling
Remote Keypad HW reset
Configuration
Address setting
Illustration
See Figure 2, Page 6, I
See Figure 2, Page 6, II
See Figure 2, Page 6, III
Mounting Instructions
See Figure 3, Page 7 to Figure 5, Page 9 (step 1 to 13) and
Figure 6, Page 10
See Figure 3, Page 7 to Figure 5, Page 9 (step 1 to 13) and
Figure 7, Page 11
See Figure 3, Page 7 to Figure 5, Page 9 (step 1 to 13) and
Figure 8, Page 12
Remote Keypad FMR-5000
Bosch Sicherheitssysteme GmbH