AUTO-ON / INTERRUPTIBLE INTERCOM
When an auto-on or intercom conversation is in progress, the concerned column or the entire system will be busy
but can be interrupted (according to the configuration of this parameter) by a call from the door unit (if "YES" is
selected).
The parameter must be programmed in the same manner on all calling stations in the system.
GUARANTEED CONVERSATION TIME
The position of the parameter determines a guaranteed conversation time, i.e. extends the busy time from
the answer onwards. The busy time is equal to the reply time (60 s) added to the guaranteed conversation
time.
The parameter must be programmed in the same manner on all calling stations in the system.
PEDESTRIAN DOOR OPENING TIME
The value of the parameter determines the pedestrian electric lock holding time (max. 90 s).
CAMERA LIGHT (#)
This parameter can be used to configure the camera LEDs to light up during the call and the auto-on function
(with audio in progress). If the value is "ENABLED", the camera LEDs light up in the steps indicated above; if the
value is "DISABLED", the camera LEDs will stay off.
AUTOMATIC DOOR OPENER
The automatic door opener function can be used to automatically open the door when you make a call from
outside to the apartment. If the value is "ENABLED" the function is active, if the value is "DISABLED" the function
is not active.
The service must also be enabled on the indoor set.
USE DOOR SENSOR FOR...
The parameter allows to enable the input for one of the following two functions:
•
"DOOR STATUS": this is used to detect the opening of the entrance door (by using an additional Normally
Closed magnetic sensor);
•
"LETTERBOX" (block): this can be used to signal the presence of mail in the letterbox (future
implementation).
CALL TONE IN PROGRESS ON/OFF
The parameter is used to enable or disable the acoustic signal on the speaker of the door unit during a call
(according to the telephone standard 1 s ON and 4 s OFF).
PRESENCE SENSOR ENABLE/DISABLE
The parameter can be used to enable or disable the presence sensor on the button panel. If the value is "ENABLED",
the presence sensor allows the automatic switching on of the display when a user approaches the sensor; the
display will switch off 60 seconds after the last activation of the presence sensor. If the value is "DISABLED", it is
necessary to press a button on the button panel to switch off the display. The display will switch off 60 seconds
after the last press of a button on the button panel.
HALL BUTTON ON/OFF
This parameter can be used to enable or disable operation of the PA terminals related to the hall button. If the
value is "ENABLED", after connecting a normally open button to the PA terminals, it will be possible to activate
the electric lock of the pedestrian door at any time (connected to the SE+ and SE- terminals); if the value is
"DISABLED", this is not possible.
CAMERA MODE (#)
This parameter can be used to select the video standard of the camera of the audio-video door unit from:
•
"PAL" (625 lines/50 Hz common in European countries);
•
"NTSC" (525 lines/60 Hz used mainly in North America and Japan).
AUTO-ON RESTRICTION ACCORDING TO APT ADDRESS PARITY (#)/(&)
The parameter enables or disables users with even ID code to be able to use auto-on video mode only on door
units with even address ID=0 (if secondary) or ID=2.
As a result, users with odd ID codes will be able to use video auto-on mode only on door units with odd address
22