Electrical data • Caracteristicas eléctricas
Charactéristiques electrique • Dados eléctricos
Max. power input
absorbida y fusible recomendado
Consommation maximale
Potência máx. absorvida
Supply voltage (see type plate)
Tensión de entrada (ver etiqueta identificativa)
Alimentation électrique (voir plaque sign.)
Tensão de rede (ver placa indicadora)
Recommanded cable jacket diameter
Diámetro exterior del cable recomendado
diamètre recommandé pour la gaine du câble
Diâmetro recomendado do invólucro de cabo
Cable cross-section and fuse protection
Sección de cable y fusible
Section des fils et fusibles
Secção do cabo e fusível recomendado
Contact loading
Carga del contacto
Pouvoir de coupure
Carga de contato
*) time lag / lento / temporisée / de ação média lenta
Maintenance • Mantenimiento • Entretien • Manutenção
12
230/110/24/...
P < 2,0 VA
Uac = ... ±10%
3 x 0,75 mm² / 5 x 0,25 mm²
x
x
Alarm
TEST
Valve
Power
24 Vdc
Vac
P < 2,0 W
U
= 24Vdc
0
-10/+25%
50 – 60 Hz
ø 5,8 - 8,5 mm
0,5 A *)
100 mA *) **)
<250Vac/<0,5A
>12Vdc/>50mA
x
x
x
x
x
x
english
Potential-free contact
The alarm signal can be relayed via a
potential-free contact. The changeo-
ver contact can be operated, e.g., in
the fail-safe mode.
When operating voltage is being app-
lied and the BEKOMAT device is
functioning correctly, the alarm relay
is energized. The contact element (0.7
- 0.8).
When there is no operating voltage or
in the case of a fault signal, the alarm
relay drops out. The contact element
is open (alarm).
Externeral test button (optional)
Here, the normal test button function
has been extended for additional use
outside the BEKOMAT unit. This
makes it possible to discharge any
condensate in the unit by remote
control, if required. When the external
contact closes, the valve will open.
**) min. internal resistance of
voltage source Ri> 12 Ohm
Maintenance recommendation:
• Housing and valve
should be cleaned once a year.
• Replace wearing parts once a year.
Set of wearing parts ( x )
BEKOMAT 12
BEKOMAT 12 CO
BEKOMAT 12 CO PN63
Functional test of BEKOMAT device:
• Briefly press test button 2 sec.
• Valve opens for condensate discharge.
Checking of alarm signal:
• Shut off condensate inflow.
• Press test button for at least 1
minute.
• Red LED flashes (after 1 minute).
• Alarm signal is being relayed.
BEKOMA
BEK
BEK
OMA
OMAT 12,
OMA
T 12, 12 CO
T 12,
T 12,
12 CO, , , , , 12 CO PN63
12 CO
12 CO
BEK
BEK
OMA
T 12,
12 CO
XE KA12 101
XE KA12 101
XE KA12 301
12 CO PN63
12 CO PN63
12 CO PN63
12 CO PN63