SETTINGS
GENERAL
•
Button tone: if the option is enabled, every time the call button is pressed a tone will be emitted (enabled
by default)
•
Confirmation tone on call sent: if the option is enabled, every time a call is made a confirmation tone will
be emitted (enabled by default)
•
Voice message language and visual indications: this option is used to activate visual indications and
voice messages assisting disabled individuals
◊
None: both visual indications and voice messages are disabled
◊
Visual indications only: when a call is sent and communication is established, and when a lock-release
command is sent, visual indications are enabled on the module
◊
[English] + visual indications: when a call is sent and communication is established, and when a lock-
release command is sent, both visual indications and the corresponding audio messages are enabled
on the module
•
Enable RTE control voice message: if the option enabled (and voice messages are enabled), upon
closure of the contact the corresponding voice message is played (disabled by default)
BACKLIGHTING LED
•
Mode: this option is used to manage nameplate backlighting using the twilight sensor supplied
◊
Auto: backlighting comes on at night and switches off during the day (default)
◊
On: backlighting is always on
◊
Off: backlighting is always off
•
Adjustment: this option is used to adjust the backlighting intensity (from 0, off, to 100, default: 100)
•
Activation threshold: this option is used to set the backlighting activation threshold (Low, Medium, High,
Maximum, default: Medium)
•
Enable Light-Me function: this function can be used to enable button backlighting only on the user's
request, by pressing the LIGHT-ME button on the audio/video module; this saves energy and reduces light
pollution. Backlighting management for this button depends on the twilight sensor setting
COMMUNICATIONS
CALL SETTINGS
•
Lock-release enabled only with forwarded call: if this option is enabled, the door entry monitor can only
trigger the electric door lock after receiving a call (disabled by default)
•
Reset after lock-release: if this option is enabled (default), after the electric door lock is triggered,
communication is stopped for the period of time set in the field "Wait time before reset (sec.)"
•
Answer wait time (sec): after a call, once this time period has elapsed without communication being
established between the audio/video module and the door entry monitor, the system reverts to standby
mode (from 10 to 120 seconds, default: 60 seconds)
•
Talk time (sec): duration of communication between the audio module and the door entry monitor. Once
this time period has elapsed, the system reverts to standby mode (from 30 to 300 seconds, default: 90
seconds)
•
Wait time before reset (sec): after the electric door lock has been triggered, communication is stopped
for this time period (from 0, immediately, to 10 seconds)
•
System busy signalling time (sec): if a call attempt is made and the system is engaged in previous
communication, a busy signal is displayed for the time period specified in this option (from 1 to 300
seconds, default: 10 seconds)
•
Call: number of calls sent to the door entry monitor when the key on the audio module is pressed
◊
Single: a single call is sent (default)
◊
Triple: 3 consecutive calls are sent
10