Relay Output - Comelit UT1020 Manual De Programación

Ocultar thumbs Ver también para UT1020:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
BUTTONS
AUDIO/VIDEO MODULE, MODULE 1... MODULE 31
Button: select the button to program, referring to the images
Function: this option is used to assign a different action to each module button
None: no action (default)
Audio call: when the button is pressed, an audio call is made to the address entered in the "Address"
field (from 1 to 240). The "Number of calls" field also appears, in which you can select the number of
calls to make to the address entered in the "Address" field (System settings or from 1 to 10)
Video call: when the button is pressed, a video call is made to the address entered in the "Address"
field (from 1 to 240). The "Number of calls" field also appears, in which you can select the number of
calls to make to the address entered in the "Address" field (System settings or from 1 to 10)
Local output control: when the button is pressed, the output set in the "Output" field is activated (SE
output for the module or Relay output for the module)
OUTPUTS
SE OUTPUT
Function: select the command which activates the SE output for the audio/video module
Lock-release: every lock-release command activates the output
Actuator control: every actuator command with the address set in the "Address sent by external
unit" field activates the output
Call sent: every call sent activates the output
Activation
Local output control (non-editable)
Output
SE (non-editable)
Enable tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field

RELAY OUTPUT

Function: select the command which activates the Relay output for the audio/video module
Lock-release: every lock-release command activates the output
Actuator control: every actuator command with the address set in the "Address sent by external
unit" field activates the output
Call sent: every call sent activates the output
Activation
Local output control (non-editable)
Output
Relay (non-editable)
Enable tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field
EVENTS
You can set the execution of several functions when specific events occur. Up to 20 events can be set.
EVENTS
No.: select the progressive number of the event
Action: select the action triggering the event
None: no action (default)
Self activation: if a door entry monitor with an address that falls within the values entered in the "From
address" and "To address" fields performs a self activation, it triggers the event specified in the
"Activation" field
Call sent: if a call is sent to a door entry monitor with an address that falls within the values entered in
the "From address" and "To address" fields, it triggers the event specified in the "Activation" field
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ut1010vcUt2020Ut2010vc

Tabla de contenido