LEGRAND 2500 VA Manual Del Usuario página 14

Reguladores de potencia
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
Technical characteristics (continued)
Protection via electronic device:
- In the case of an overload and above the max. operating temperature the product automatically regulates the power
by reducing the lighting level (the illuminated indicator turns orange).
- In the case of a very high overload the remote control dimmer switches off (the illuminated indicator turns red). Once
the fault has disappeared it can be switched back on by pressing the local control button and holding it down for > 3
s (the illuminated indicator turns green). The product is then ready to be used.
- In the event of a short-circuit: protection via fuse (the illuminated indicator is off)
400 81: 10.3 mm x 31.5 mm - 16 A - 400 VAC (Cat. No. 126 16)
400 83: 10.3 mm x 31.5 mm - 20 A - 400 VAC (Cat. No. 126 20)
Own consumption: 400 81 = 21 W - precharging unit 15 W
400 83 = 45 W
Storage temperature: - 5° C to + 65° C
Operating temperature: - 5° C to + 35° C (derating above 35° C)
Capacity of connection terminals:
- Power supply / Use: 2 x 2.5 mm
- Control pushbuttons and auxiliaries: 1 x 1.5 mm
Construction conforming to the following standards: NFC 61 111 / IEC 669-2-1
Note:
To achieve the same level of dim-
ming at each light spot, use iden-
tical bulbs, ballasts and transfor-
mers (same secondary voltage and
power).
Description
Illuminated indicators
Green = Operating
Orange = Overload
Red = Inoperative
Off = Short-circuit
Local control
or 1 x 4 mm
rigid or flexible wire with cable end
2
2
2
Important:
- The connection diagrams must be followed to avoid damaging the
device.
- The upstream protective device must be opened before any intervention
on the lighting circuit.
- This product must be installed and the protective device maintained by a
qualified person doivent être assurées par une main d'œuvre qualifiée.
230 V
2500 W
H G F E D C B A
Power
Control
extension
terminals
terminals
- Lighting adjustment button (if the
- Min. lighting level adjustment button
15
1
13
3
11
5
9
7
T V E
400 81
Function switch:
N
P
14
function switch is in the "V" posi-
tion).
(if the function switch is in the "T"
position).
T = remote control dimmer
V = dimmer
E = slave
N

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5000 va

Tabla de contenido