ELECTRICAL CONNECTIONS
J1
+/- - Power supply 12 ÷ 24 V ac / dc
J2
A - RS485-A => for pre-arranged RIB control boards (L1, L1 24V, B2, B2 24V, P1, P1 24V)
B - RS485-B => for pre-arranged RIB control boards (L1, L1 24V, B2, B2 24V, P1, P1 24V)
1 - COM OUT START => Common of motion command
2 - OUT START => Motion command (NO)
3 - IN SIGNAL => Input of the gate open signal.
4 - COM IN SIGNAL => Common of the gate open signal.
ESP1 => Connector for Wi-Fi / RJ45 module.
ESP2 => Connector for radio module.
J-USB - unmounted connector => will only be used in the benchtop programmer version as a board power connector (no need of power from J1)
RTC => Connector for clock module
JUMPERS JP1 AND JP2
The jumpers between 1 and 2 make it possible to externally connect the clean contact provided by a control unit for open gate signaling.
The jumpers between 2 and 3 (default) allow to connect a voltage signal from 5 to 30 Vdc (SIGNAL) for the signal of open gate.
SETTING TO RECEIVE A "GATE OPEN" SIGNAL USING A VOLTAGE
JP2 JP1
SETTING TO RECEIVE A "GATE OPEN" SIGNAL USING A CLEAN CONTACT
JP2 JP1
DL1 led (green) flashing. It is used to signal correct operation.
· LED flashes every 1 second
· LED flashes every 3 seconds
· LED off
· LED on steady
+/- 5÷30 Vdc
> correct operation with control unit (L1 - L1 24V - B2 - B2 24V - P1 - P1 24V)
> correct operation of the relay or failure to communicate with the control unit (serial interrupted)
> failure or power failure
> card locked (remove and restore current)