Care and Maintenance

Be sure to unplug the unit before cleaning
To clean the exterior of your unit:
Use a clean, damp cloth with water; do not use any abrasive detergent.
To clean the air inlet and outlet:
Clean the dust on or around the air inlet with a dry cloth.
Clean the dust on or around the air outlet with the nozzle of a vacuum
(refer to the Product Diagram, Figure 1-2).
To clean the Filter Cartridge:
• For effective filtering clean the dust on and around the cartridge with the nozzle of a
vacuum at least every 2 weeks.
• The Nano Silver Coated Pre-filter attaches to the Filter Cartridge with velcro and can
be removed for cleaning. This portion can be cleaned under running water but must
be dried throughly before reattaching it to the Filter Cartridge. This means it must air
dry for at least 4 hours after the excess water as been shaken off.
• Never use water or any cleaning solution to clean the cartridge.
Replacing the Filter Cartridge
The Filter Cartridge will filter for approximately 4,000 hours before needing replacement.
Excessive contaminants in the air will shorten this lifespan, so if you notice that your
filtering is no longer effective, you should replace the Filter Cartridge. The Filter Cartridge
is easy to replace and completely disposable.
You may purchase replacement Filter Cartridges from your Rena Ware representative or
the Customer Service Center near to you. You may also visit Rena Ware on the web at
the www.renware.com for information on our Service Centers. See the Customer Service
Center listing on separate enclosed sheet.
When requesting a replacement Filter Cartridge, refer to item #4002.
How to remove the Filter Cartridge
A. Turn off the unit and unplug it from the outlet.
B. Remove the front cover by grasping the lower left and right corners of the front panel
and pull it up and out (Figure 5).
Figure 5
Open from bottom. Lift up
8
Figure 6
Active carbon filter with HEPA Pre-filter
(Nano silver mesh outside)
Figure 7
Retaining
Latch
Rotate the retraining latch 45°; remove the cartridge as shown in figure 7.
Active carbon filter
with HEPA Pre-filter
(Nano silver mesh
outside)
Figure 8
Figure 9 - Replace front cover
Retaining Tabs
C. Rotate the cartridge retaining latch
to the left or right 45° and pull
the cartridge out by the bottom.
Remove any packaging from the
new cartridge.
D. Gently push the top of the new
cartridge into the unit until it
touches the back; then push in the
bottom. Rotate the retaining latch
to hold the cartridge in place.
E. Reattach the front cover, by
aligning the two top tabs and
pushing the bottom of the panel
to reattach the two bottom posts.
F. Plug the unit in and turn it on. Hold
the "Sleep" button for five seconds
to reset the Filter Replacement
indicator light.
9