− Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
− Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating instructi-
ons.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− Only operate the unit if no persons are in the water!
− Keep the socket and power plug dry.
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
The unit can only be operated with the filter wings attached to the pump body (A = delivered condition) or with a sepa-
rate filter wing adapter (B).
Fit the nozzle tube
Fit the bottom nozzle tube (6) through the blue union nut, screw connect the ball bearing, fit the top nozzle tube
through the black union unit and bolt this to the bottom nozzle tube.
Bolt the nozzle holder (7) on the top tube, screw in the desired nozzle, then loosely screw the union nut on the top
outlet of the pump filter.
Set-up the unit
Place the unit and, if applicable, the filter wing adapter in the pond as horizontal as possible on a firm, sludge-free
ground, ensure that it is completely covered with water, at a maximum of 2.0 m below the water level. Set the nozzle
tube to the desired height and inclination above the water surface, then fasten the blue union nut.
Attention! Never operate the unit without water!
In operating mode (A) swivel the filter wings on the pump filter upward. Optional water spitters are fitted to a regulating
connection (3), the OASE-lights to the light holders (4).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Attention! The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down. Risk of accident!
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).