Specifications
Vacuum tightness:
Output signal:
Power Supply:
Total Current consumption:
Atmospheric pressure:
Humidity:
Nominal position:
Accuracy:
Measuring rate:
Non-linearity:
Temperature error:
Settling time:
Long-term stability:
Ingress protection:
Vibration resistance:
Shock resistance:
Service life:
Free fall test:
Medium Temperature:
Ambient Temperature:
Storage Temperature:
2
Yes
SAE J1939
10 to 30 Vdc (24Vdc typical)
< 40mA
860 to 1060 mbar
45 to 75 % relative
Calibrated in vertical mounting position with pressure connection facing downwards
≤ ± 1% of span
Maximum 1000 Hz
≤ ± 0.2% of span BFSL
Temperature compensated in the range from -40 to 85 °C
•
Temperature range 0 to 60 °C: ≤ 0.5% of span
•
Temperature range -20 to 85 °C: ≤ 1% of span
•
Temperature range -40 to 0 °C: ≤ 1% of span
≤ 1.5 ms (Baud rate ≥ 125k)
≤ ± 0.2% of span/year
IP 6K9K, when plugged in using a mating connector that has the appropriate ingress protection.
20 g
500 g
> 10 million load cycles
Resistant to an impact onto concrete from 1m
-40 to 125 °C
-40 to 85 °C
-40 to 100 °C