Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
g.
The immunity of other equipment in which the equipment is to be used. The user must ensure that other
equipment used in the same place is compatible. This may require additional protection measures;
h.
The time of day when welding or other activities are carried out
i.
The size of the area to be considered will depend on the structure of the building and any other
processes in the area. The surrounding area may extend beyond the boundaries of the buildings.
Recommendation to reduce electro-magnetic emission
Mains power supply: the equipment must be connected to the power mains as specified in the
a.
Manufacturer's instructions. If interference occurs, additional precautions such as filtering of the mains
supply may be required. The supply cable in the welding machine's permanent installations may have to
be screened in metal conduits or similar. The screening should be electrically continuous for the entire
length of the cable. It should also be connected to the welding machine with a good electrical contact
between the metal conduit and the casing.
Welding cables: The welding cables should be kept as short as possible and should be positioned close
b.
together, running at or close to the floor level.
Protection and reinforcement: Selective screening and shielding of other cables and equipment in the
c.
surrounding area may alleviate problems of interference. Screening of the entire welding area may be
considered for special applications
Connect the earth directly to the metal piece to be welded: Where necessary, the connection of
d.
the workpiece to earth should be made by a direct connection to the workpiece, but in some countries
where direct connection is not permitted, the bonding should be achieved by suitable capacitance,
selected according to national regulations.

TROUBLESHOOTING

Anomalies
The device does not deliver any
current and the yellow indicator
lamp of thermal defect
up.
The display is on but the device
does not deliver any current.
If, when the unit is on and you
put your hand on the welding
unit's body, you feel tingling
sensation.
The display is on but the device
does not deliver any current.
When starting up, the display
indicates
.
Instable arc
The
tungsten
oxidised and tern at the end of
welding.
The electrode melts
The welder thermal protection
has turned on.
lights
The cable of the earth clamp or
electrode holder is not connected
to the welder.
The welding unit is not correctly
connected to the earth.
The cable of the earth clamp or
electrode holder is not connected
to the welder.
The voltage is not included in the
range 230V +/- 15%
Default
tungsten electrode
Too important gas flow rate
Welding zone
electrode
gets
Default coming from post-gas or
the
gas
prematurely.
Polarity error
Causes
coming
from
the
has
been
stopped
Remedies
Wait for the end of the cooling time,
around 2 minutes. The indicator
lamp
turns off.
Check the connections.
Check the plug and the earth of
your electrical network.
Check the connections.
Have the electrical installation
checked.
Use a tungsten electrode with the
adequate size
Use
a
well
prepared
electrode
Reduce gas flow rate
Protect welding zone against air
flows
Check
and
tighten
connections. Wait until the electrode
cools down before stopping the gas.
Check that the earth clamp is really
connected to +
tungsten
all
gas
12

Publicidad

Tabla de contenido
loading

Tabla de contenido