Herth+Buss 95980775 Instrucciones De Operación página 41

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instruction
Temperature
Range
−20 – 1000 °C
−4 – 1832 °F
Overload Protection: Fuse, 500mA / 250V, fast action.
Note:
1. Accuracy does not include error of the
thermocouple probe.
2. Accuracy specification assumes ambient
temperature is stable to ± 1°C. For ambi-
Dwell Angle
Cylinders
Range
2
0 – 180°
3
0 – 120°
4
0 – 90°
5
0 – 72°
6
0 – 60°
8
0 – 45°
Input Voltage: 3 – 50 Vp
Required Engine Rotation Speed: 250 RPM – 40 kRPM
Overload Protection: 250 V DC/AC
41
Resolution
1 °C
1 °C
1 °C
1 °F
1 °F
1 °F
ent temperature changes of ± 5°C, rated
accuracy applies 1 hour later after the
temperature change.
Resolution
0,1°
0,1°
0,1°
0,1°
0,1°
0,1°
95980775
Accuracy
−20 – 0 °C: ± (6,0 % + 5)
0 bis 400 °C: ± (1,5 % + 5)
>400 °C: ± (1,8 % + 5)
−4 bis 32 °F: ± (6,0 % + 9)
32 – 752 °F: ± (1,5 % + 9)
>752 °C: ± (1,8 % + 9)
Accuracy
± (2,5 % + 5)
± (2,5 % + 5)
± (2,5 % + 5)
± (2,5 % + 5)
± (2,5 % + 5)
± (2,5 % + 5)