SETTING UP
After completing all the wiring and cable connections, and the above mentioned settings or after each A4 Resetting, have
skilled, qualifi ed staff restart the operator, by fi rst running the following functions:
- type of motor (A1);
- number of motors (F46);
- motors test (A2)
Auto-learning of the gate travel (A3).
Motor type
The control board is not confi gured for automating the gearmotor. You need to confi gure it by setting function A1 as follows:
Select A1.
Press ENTER to confi rm.
Select 6 and press ENTER to confi rm the operation.
Number of motors
The control board is confi gured to control two gearmotors. To control just one gearmotor, set function F46 as follows:
Select F46.
Press ENTER to confi rm.
Select 1 and press ENTER to confi rm the confi guration for just
one gearmotor.