Attach the Adapter Plate to the Panel
1. Align the studs on the cutout adapter plate with the existing stud holes on
the front of the panel.
2. Place the adapter plate into the front of the panel cutout until the sealing
gasket material is firmly against the front of the panel.
Nut and Washer
Inside of Panel or Enclosure
3. Using nuts with flat washers, fasten the cutout plate onto the studs until the
sealing gasket is slightly compressed against the front of the panel.
4. Using the torque wrench, tighten the nuts to not more than 1.92 Nm (17
lb-in) to maintain a NEMA Type 4X rating.
Do not overtighten.
Adapter Kit for PanelView 1400e Touch Terminal Cutout
Publication 2711P-IN011C-MU-P - March 2007
Adapter Plate
Front of Panel or Enclosure
5