Periodic Maintenance - EemaX LavAdvantage Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EX07200-121 Rev A
Two flashes once,
Low heat
three second pause
Two flashes twice,
Outlet thermistor failure
three second pause
Two flashes three
Over-temperature
times, three second
Warning
pause
Three flashes once,
Over-temperature
three second pause
Protection
Three flashes twice,
Freeze warning
three second pause
The heater is designed for many years of carefree use. In order to maintain consistent water flow, it may be necessary to periodically
clean the faucet aerator or the filter screen located in the brass inlet fitting at the heater.
Element cartridge
installs inside heating chamber of all
heaters
Relay
Electrical cut-off
(ECO)
Terminal block
Control board
Manufacturer's National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Information contained in this document is subject to change without notice.
- outlet temperature below 90°F/32°C
for 5 seconds of flow
- element failure
- ECO tripped/malfunctioning
- relay/contactor malfunctioning
- control board failure
- inlet water supply out of spec
- outlet thermistor interrupted or
disconnected
- outlet temperature exceeds
110°F/38°C
- outlet temperature exceeds
150°F/65°C
- inlet temperature is too low (below
35°F/2°C)

PERIODIC MAINTENANCE

FlowCo
- unit keeps running,
LED flashes a warning
pattern
- unit keeps running,
LED flashes a warning
pattern
- unit keeps running,
LED flashes a warning
pattern
- unit stops heating until
outlet temperature falls
below preset minimum
- heating disabled
LavAdvantage & Accumix II
- reduce flow through
unit
- inspect
connections/wiring of
outlet thermistor
-increase flow through
unit. If this temperature
is desired no action is
required
- increase flow through
unit to decrease the
overall temperature rise
- increase temperature of
inlet water to meet
product specifications
Triacs
Heating chamber
Triacs
Contactor