HIDDY 350D
3.5 Electrical connection
To be undertaken after disconnecting the power supply to the
engine control unit. Refer to the directions of Fig. 8.
3.6 Emergency release
To be carried out after having disconnected the power supply to
the motor.
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the physical effort necessary to move the gate leaf should not be
higher than (values indicated of the EN 12453 norm) .
In the case of a power cut, the gate can be opened manually by releasing
the lock on the operating lever to allow the gate to move freely.
IMPORTANT:
Please make sure that the leaves stop against the mechanical
stoppers inside the operator before they reached the
ground mechanical stopper. In not adjusted, unblocking will
be impossible.
3.7 Electrical safety devices
The installation must be installed according to the current regulations
and laws. Use the ECA5.W electronic control unit. For connections and
technical data of accessories refer to the appropriate booklets.
3.8 Maintenance
To be undertaken by specialized staff after disconnecting power
supply.
Make certain that moving parts located inside the box are greased once
a year, and check the force transmitted through the drive to the gate.
In the event that the need for servicing or repairs should arise, the speed
reducer can be removed from the box without taking down the gate.
- Lift the cover from the box, isolate the motor from the power supply by
disconnecting the cable, then remove the curved lever: the gate can
now swing freely.
- Then unscrew the for nuts that fix the motor.
8
Common
C
B
EN
Yellow- Green
Common
Blue
Brown
C
Black
EIS5.L
8
9