Folder system
4. Folder system
The previous point outlines the folder structure that the USB memory must possess in order for the parameters to
be correctly loaded in the station. If this structure is not followed, the parameters will not be loaded.
The purpose of each folder is described below. It may not be necessary to use certain folders. If you do not require
the station firmware to be modified, it is not necessary to include the firmware folder on the USB memory. This
also applies to the rest of the folders.
4.1. Bootloader
The bootloader firmware must be placed in this folder if an update is necessary. The extension of the bootloader
filename is .bin.
4.2. Config
This folder contains the files required to configure the charging station. In order to configure the station, it
is necessary to modify the date.ini file (to adjust the date and time) and the user.ini file (to configure certain
parameters).
The documents howto_date.ini and howto_user.ini contain information about the configuration.
date.ini
In order to adjust the date and time of the charging station, the date.ini file must be modified, writing a single line
that includes the current date and time, in this format:
mmm: the three first letters of the name of the month (jan, feb, mar, apr, may, jun, jul, aug, sep, oct, nov,
dec).
dd: day. Always use two figures (01, 03, 12, 20, etc.).
yyyy: year (2013, 2014, etc.).
hh: hour. Always use two figures (01, 07, 15, 21, etc.).
mm: minute. Always use two figures (03, 09, 17, 36, etc.).
ss: second. Always use two figures (04, 08, 12, 25, etc.).
After modifying this parameter with the required date and time, the USB memory must be connected to the station
at that exact time so that the update is correct.
Once the date and time of the station have been updated, the date.ini file will be deleted from the USB memory to
prevent erroneous updates.
user.ini
The user.ini file contains the variables that can be configured by the user. Not all the parameters can be configured
in all models, but they are included for reasons of compatibility.
If there is a user.ini file in the folder /gewiss/config/ when a USB memory is connected to the station, the new
configuration will be loaded.
The configurable parameters are:
language
Defines the user interface language for units with a screen.
Example:
language = "es";
country
Defines the country, reserved for future developments.
Example:
ABA2023IQM05_ - 7.55.4.186.2 - Configuration
mmm dd yyyy hh:mm:ss
Gewiss
EN
ES
FR
IT
9