The "RI.15K" control unit with microcontroller is suitable for motors with up to 750W power.
Installation instructions.
a)
The electrical installation and functioning logic must comply with current standards.
b)
Keep the power cables (for the motor and power supply) away from the control cables (buttons,
photocells, radio). To avoid interference use two separate sheaths (see EN 60204-1 15.1.3).
c)
Check all the connections again before supplying voltage.
d)
Check that the Dip-Switch settings are as required.
e)
When voltage is supplied, the "POWER" led should light up. If this is not the case, check the state
of the fuses and whether 230VAC 50 Hz power is present between terminals 1 and 2 (INPUT 230VAC
- respect phase/neutral wire position).
f)
The N.C. inputs not used must be connected to the common "+V".
g)
If the direction of the motor rotation is not correct, invert the "OPEN" - "CLOSE" wires of the motor
as well as the wires of the "FCA" - "FCC" limit switches.
Input/Output functions
(1,2)
INPUT 230VAC= Control unit 230VAC 50 Hz power supply
(3,4,5)
COM/APRE/CHIUDE= Connection to the corresponding 230VAC 50 Hz motor terminals
(6,7)
LAMP230= Connection to the 230VAC blinker.
(19,20) OUT 24VAC= 24VAC auxiliary power supply output (1A max.).
(17,18) SCA= "Gate open warning light" contact.
(15,16) +V= Common connection to all the control inputs.
(14)
FTC= Photocell receiver input (n.c. contact).
(13)
FCA= Limit switch input - Opening (n.c. contact).
(12)
FCC= Limit switch input - Closing (n.c. contact).
(11)
STOP= STOP button input (n.c. contact).
(10)
P.P.= STEP-by-STEP button input (n.o. contact).
(9)
APRE= OPEN button input (n.o. contact).
(8)
CHIUDE= CLOSE button input (n.o. contact).
(23,24) ANT.= Input of radio board antenna
(21,22) RX 2CH.= Radio board 2nd channel contact (n.o. contact).
(J2)
SENS_H= Input for optional anti-crash card "DA.AS"
1-2 pin: 24Vdc power supply (1 + ; 2 - )
2-3 pin: n.c. contact input
or for any other n.c. safety device (pneumatic profile, photocells, etc.)
2-3 pin: n.c. contact input;
the activation of the device connected to these terminals causes the stopping or the
reversion movement of the motor.
Note: Pins 2 and 3 must be short-circuited if not in use.
6
RI.15K Control unit with microcontroller
(respect phase/neutral wire position).
(the earth wire (green/yellow) must be connected to the motor housing).

Publicidad