Descargar Imprimir esta página

Stannah Starla 260 Manual De Instalación página 18

Ocultar thumbs Ver también para Starla 260:

Publicidad

Powered Swivel Diagnostic & Configuration Diagram 2609189
DIAGNOSTICS
LED No.
DESCRIPTION
FLASHING = MOTOR FAULT
L1 (Red LED)
ON = PCB FAULT
L2 (Yellow LED)
ON = SWIVEL CENTRED
FLASHING = OVER CURRENT FAULT
L3 (Red LED)
ON = LOW VOLTAGE FAULT
FLASHING = ENCODER SEQUENCE FAULT
L4 (Red LED)
ON = MISSING ENCODER FAULT
L5 (Yellow LED)
ON = VALID CALL EXISTS
FLASHING = PCB OK AND COMMS OK
L6 (Green LED)
ON = NO COMMS WITH CARRIAGE CONTROL PCB
*
If resetting power does not clear encoder sequence fault, this is due to the fault occurring during an
inwards swivel operation. To rest fault, use the following method:
Switch off power
Set both switches of SW1 to OFF position
Switch power ON
Switch power OFF and reset switches to desired configuration (see direction setting below)
Switch power ON
SWIVEL DIRECTION SETTING
The default of the swivel board dip switch (SW1) allows outward swivel in both directions.
To reconfigure the swivel to operate as required, use the following procedure:
Switch OFF power
Set 'R' switch of SW1 to OFF position to disable right outward swivel or set 'L' switch of SW1 to
OFF position to disable left outward swivel
Switch power ON
Check for correct function of swivel system
FAULT CLEARING
REMOVE AND RE-APPLY POWER
REMOVE AND RE-APPLY POWER
REMOVE AND RE-APPLY CALL
REMOVE AND RE-APPLY CALL
REMOVE AND RE-APPLY POWER*
REMOVE AND RE=APPLY POWER

Publicidad