Powered Swivel Diagnostic & Configuration Diagram 2609189
DIAGNOSTICS
LED No.
DESCRIPTION
FLASHING = MOTOR FAULT
L1 (Red LED)
ON = PCB FAULT
L2 (Yellow LED)
ON = SWIVEL CENTRED
FLASHING = OVER CURRENT FAULT
L3 (Red LED)
ON = LOW VOLTAGE FAULT
FLASHING = ENCODER SEQUENCE FAULT
L4 (Red LED)
ON = MISSING ENCODER FAULT
L5 (Yellow LED)
ON = VALID CALL EXISTS
FLASHING = PCB OK AND COMMS OK
L6 (Green LED)
ON = NO COMMS WITH CARRIAGE CONTROL PCB
*
If resetting power does not clear encoder sequence fault, this is due to the fault occurring during an
inwards swivel operation. To rest fault, use the following method:
Switch off power
•
Set both switches of SW1 to OFF position
•
Switch power ON
•
Switch power OFF and reset switches to desired configuration (see direction setting below)
•
Switch power ON
•
SWIVEL DIRECTION SETTING
The default of the swivel board dip switch (SW1) allows outward swivel in both directions.
To reconfigure the swivel to operate as required, use the following procedure:
Switch OFF power
•
Set 'R' switch of SW1 to OFF position to disable right outward swivel or set 'L' switch of SW1 to
•
OFF position to disable left outward swivel
Switch power ON
•
Check for correct function of swivel system
•
FAULT CLEARING
REMOVE AND RE-APPLY POWER
REMOVE AND RE-APPLY POWER
REMOVE AND RE-APPLY CALL
REMOVE AND RE-APPLY CALL
REMOVE AND RE-APPLY POWER*
REMOVE AND RE=APPLY POWER