Technical Data Sheet - Cattini Oleopneumatica YAK 203 Manual Uso Y Mantenimiento

Gato neumático
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN

TECHNICAL DATA SHEET

Working air pressure
Working temperature
Air consumption
Compatible oils
Pneumatic system pipes
Aerial Noise
Acoustic radiation pressure measured: 60 dBA
Tests carried out in conformity with the standards ISO/R 1680 - 1970. Instrument: LARSON DAVIS 800 B PRECISION ANALYSER
PHONOMETER in conformity with the standards IEC 804 E 651 class 1 set with a Larson Davis Ca 250 114/b 250 Hz calibrator
before and at the end of the measurements.
Measurements and dimensions - YAK 203
8 > 10 bar
116 > 145 psi
-20°C > +50°C
-4°F > 122°F
100 nl/min
ATF Dexron IID
-
17 Kg
Weight
37 lb
285 mm
Max. stroke
11.2 in
2 t
Capacity
2 ton (short)
B
C
D
415 mm
16.3 in
250 mm
9.8 in
205-490 mm
8.1-19.3 in
15

Publicidad

Tabla de contenido
loading

Tabla de contenido