HANG UP THE FAN (Fig. 3)
1. Lift the fan assembly with canopy (4) to the mounting bracket (1).
2. Hang up the fan assembly by securing the steel cord (3) onto the J-hook of the mounting bracket (2).
3. Insert the remote receiver into canopy (4).
PREPARE AND COMPLETE THE ELECTRICAL WIRING --- WIRING DIAGRAM (FIG. 3)
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED
ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.
PLEASE MAKE SURE THE MAIN SWITCH HAS BEEN TURNED OFF BEFORE CONNECTING
• Connect "LIVE" supply wire to the "L" of terminal block on the mounting bracket.
• Connect "NEUTRAL" supply wire to the "N" of terminal block on the mounting bracket.
• Connect "EARTH" wire to the "
• Connect the output connector (A) from the receiver to the connector (A) from the fan body.
• Connect the connector (B) from the fan mounting bracket to the input connector (B) from the
receiver.
• Connect the connector (C) from the infrared detector to the input connector (C) from receiver.
Fig. 3
6 | P a g e
" of terminal block on the mounting bracket.