De la Cableado del control
Field Wire Diagram - 1862-010 Control Board
Phone Line Wiring Max Distance
Phone
800 Feet
24 AWG
Line
1600 Feet
22 AWG
1
16 Volt, 20 VA UL Listed power transformer.
Power for door strikes or magnetic lock is not provided by the
2
system. It must be provided by an external power supply.
Electric strikes are wired to Normally Open (N.O.) contacts; magnetic
3
locks are wired to the Normally Closed (N.C.) contacts.
Optional 12 Volt gel cell for backup power.
4
Dedicated Central Office (C.O.) phone line - touch tone, loop start.
5
A switch closure across terminals 4 & 8 will activate relay 1 for its programmed
6
strike time. This is where the postal switch is prewired.
A switch closure across these terminals will activate relay 2 for its programmed strike
7
time or cause the system to dial a preprogrammed phone number. See 3.1.6.
All wiring to be performed in accordance with National Electric Code.
Strike /
Mag Lck
3
1
SWITCH 2
INPUT
2
7
MAIN TERMINAL
1
2
3
4
5
5
Gate
Operator
Lock
Pwr
2
NO NC COM
RELAY 2 CONTACTS
6
7
8
9
10 11 12 13 14
6
4
Lock
Pwr
2
25
1862-010
Circuit Board
Power Wiring Max Distance
PWR
100 Feet
18 AWG
INPUT
200 Feet
16 AWG
1
Gate
Operator
Strike /
Mag Lck
3