1 Robotclean Accu Operating Instructions and Parts List
Tips and Hints
- The pool cleaner and filter insert should be cleaned after each use.
- The pH-value of the pool water should be between 7.0 and 7.4.
- Water temperature should be between 10°C and 32°C
Status
Switching ON
Switching OFF
Automatic return
Pause on reversing
Working cycle has ended
Einstellung 1: 0°/20° Standardeinstellung für die meisten Pools.
Low Voltage
Water inside
Pump protection mode
Trouble Shooting
Fault
Einstellung 2: 0°/40° wenn der Poolreiniger das Becken nicht vollständig abdeckt.
The pool cleaner does not work and the control
light does not flash
The adapter control light does not work
The pool cleaner does not work and the yellow
control light flashes slowly
The pool cleaner does not work and the red control
light flashes slowly.
The pool cleaner does not clean in all places.
Einstellung 3: 20°/20° für runde Becken.
The pool cleaner does not work and the blue control
light flashes.
MAINTENANCE
For cleaning use a commercial care product.
Do not use any cleaning products containing solvents or scouring agents, or hard sponges, brushes etc.
Öffnen und Schließen des Gehäuses
Cleaning the filter unit
CLEAN THE FILTER UNIT AFTER EACH CLEANING CYCLE
- Place the pool cleaner onto a level, clean surface and remove the upper housing by pressing the buttons on each side.
Cause
Function for the protection of the battery
The adapter is damaged
Low battery capacity
Fault in the pool cleaner
Nozzle angle incorrect
Special pool shape
The water circulation of your pool is switched on
Function for the protection of the pump
Öffnen
Indicator
Continuous light flashes blue
Continuous light flashes red
Blue light flashes
Rotes light flashes
The yellow light flashes three times and then shows constantly until the power supply is
switched off.
Yellow light flashes
Red light flashes
Blue light flashes slightly
Solution
Charge the robot
Contact the customer service
Contact the customer service.
Charge the battery
Contact the service centre
Adjust nozzle angle
Adjust nozzle to enlarge cleaning angle
Switch off the filter pump
Re-start the pool cleaner
Schließen