EMPTYING & CLEANING THE COLLECTION TANK
28
29
1. Verify that the battery has been removed from the operational battery bay (Fig. 28).
2. Disconnect the hose from the vacuum.
3. Undo the latches and remove the power head from the collection tank.
4. Clear all dirt or debris from the collection tank and clean with mild soap and water. Allow to dry
before replacing the power head (Fig. 29).
STORAGE
Before storing your vacuum cleaner, the collection tank should be emptied and cleaned. The
battery should be stored in the right storage bay. The accessories should be cleaned and stored
so they can be readily available when needed. Store wet/dry vacuum indoors.
REPAIRS
Repairs for this wet/dry vacuum should be performed only by qualified service personnel using
only identical replacement parts.
INSTALLING & CLEANING CARTRIDGE
FILTER
30
31
32
33
INSTALLING CARTRIDGE FILTER
1. Verify that the battery is disconnected (Fig. 30).
2. Remove power head and place in an upside down position.
3. Install the cartridge filter over the filter cage, securing it with the retainer nut. Do not over-
tighten (Fig. 31).
REMOVING & CLEANING CARTRIDGE FILTER
1. Unscrew the retainer nut by turning counter clockwise (Fig. 32).
2. Carefully hold and pull the cartridge filter up for removal.
3. Clean the cartridge filter by brushing or rinsing off the debris (Fig. 33).
4. Install cleaned or new filter as instructed in steps 2 & 3 of INSTALLING CARTRIDGE FILTER.
5. Wet filters should be removed and allowed to air dry for 24 hours before installing onto the filter
cage.