ALWAYS disconnect your SOLAR power inverter from the 12 Volt power source prior
to opening the fuse panel or attempting to replace the fuse(s). ALWAYS use the proper
replacement fuse(s) as indicated in the chart above. Make sure to address the root
source of the overload that caused the blown fuse prior to using your power inverter
again.
TROUBLESHOOTING
Problem:
Low or no output voltage from the power inverter
Answer:
Check connections between the 12 Volt power source and the power
inverter as detailed in Connecting Your Power Inverter.
Answer:
Using the incorrect type of voltmeter to test the output voltage. To
accurately measure the the output voltage of your SOLAR Power
Inverter, use only a voltmeter identified as a "True RMS" reading
voltmeter.
Problem:
Red LED ON
Answer:
The voltage of the 12 Volt power source may have dropped below 9.5
Volts – check 12 Volt power source voltage and recharge as needed.
Answer:
The device being powered is placing a power demand on the inverter
that is beyond its operating capacity – use a higher capacity power
inverter or cease powering that device using your power inverter.
Answer:
The inverter is too hot – allow the inverter to cool. Check for adequate
ventilation. If problem persists, reduce the the load on the power inverter
to the rated continuous power.
Problem:
Low Battery Alarm on Continuously
Answer:
The voltage of the 12 Volt power source may have dropped below 10.5
Volts – check 12 Volt power source voltage and recharge as needed.
Answer:
Poor or weak 12 Volt power source – recharge or replace the battery.
Answer:
Inadequate power delivery from the 12 Volt power source – check the
connections between the 12 Volt power source and the power inverter.
Problem:
Poor Television/Audio Device Reception
Answer:
Refer to "Suggestions When Using Your Power Inverter to Power
Television and Audio Devices" section within this Operator's Manual.
Replacement Parts and Accessories for SOLAR Power Inverters
Part No.
248-004-666
248-006-666
248-007-666
248-008-666
SOLAR Power Inverter USER'S MANUAL
Description
Connection cables for 400 W inverter
Connection cables for 800 W inverter
Connection cables for 1200 W inverter
Connection cables for 2400 W inverter