Mechanical Installation
Position the module clamps uniformly
on the solar module in accordance with
the following graphic. In doing so, ensure
that D is not below 170 mm and does not
exceed 400 mm.
D
D
170 mm ≤ D ≤ 400 mm
Permitted position of the module clamps
If you are mounting several solar modules
next to each other, place a distance piece
between adjacent solar modules. The
solar modules should never be mounted
directly next to each other, since the so
lar modules may sustain damage owing
to temperatureinduced variations in their
dimensions. A minimum distance of 5 mm
is recommended.
D
D
Distance between the solar modules
EN