GB TUTA PROKEM Manual Del Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
TUTA PROKEM PERFORMANCE
TEST
ENTIRE GARMENT
Spray test
Penetration resistance to solid fine particles
Penetration resistance to radioactive particulates
Stitch resistance
MATERIAL
Resistance to abrasion
Resistance to tearing
Tensile strength
Resistance to perforation
Resistance to bending
Resistance to ignition
Surface electrical resistance
Penetration resistance to contaminated liquids under hydrostatic
pressure - synthetic blood. Bacteriophage PhiX174.
Penetration resistance to infective agents due to mechanical
contact with substances containing contaminated liquids
Penetration resistance to contaminated liquid aerosols
Penetration resistance to contaminated solid particles
CAS
Penetration resistance to liquid chemical agents
7664-93-9
Sulphuric acid H
SO
2
1310-73-2
Caustic soda NaOH 10%
106-42-3
o-xylene
71-36-3
Butan 1 ol
CAS
Repellency to liquid chemical agents
7664-93-9
Sulphuric acid H
SO
2
1310-73-2
Caustic soda NaOH 10%
106-42-3
o-xylene
71-36-3
Butyl alcohol
The performance levels are based on laboratory test results and could differ from
actual existing workplace conditions. A preliminary test should be carried out to verify
the effective suitability for the desired use. The protective characteristics refer to the
new PPE in good condition, never subjected to cleaning.
METHOD
EN ISO 17491-4 method B
EN ISO 13982-2
EN ISO 13982-2, EN 1073-2
EN ISO 13935-2
EN 530 metodo 2
EN ISO 9073-4
EN ISO 13934-1
EN 863
EN ISO 7854 method B
EN 13274-4 method 3
EN 1149-1
EN 14126, ISO/FDIS 16603,
ISO/FDIS 16604
EN 14126, ISO/DIS 22610
EN 14126, ISO/DIS 22611
EN 14126, ISO/DIS 22612
EN 368
30%
4
EN ISO 6530
30%
4
RESULT
No penetration
L
,
30% , L
,
15%
jmn
82/90
s
8/10
TIL
: 2,39% - N.p.F. 41,8
A
120 N
60 cycles
20.8 N
55 N
18.3 N
> 100.000 cycles
Self-extinguishing material
2.5 x 10
9
14.00 KPa
T > 75 min.
Log > 5
Log ufc
1
0.0%
0.0%
0.0%
0.0%
96,4%
94,6%
89,6%
92,5%
* The surface resistance depends on the relative humidity: the lower the relative
humidity, the higher the resistance. The test was carried out in an environment with
a relative humidity of 25%.
CLASS
passed
passed
1
3
1
2
1
2
6
passed
5
6
3
3
3
3
3
3
3
3
1
2

Publicidad

Tabla de contenido
loading

Productos relacionados para GB TUTA PROKEM

Este manual también es adecuado para:

494060

Tabla de contenido