TECHNICAL DATA SHEET [EN]
FEATURES
Series 4000
reusable full face masks are designed to be used with a double bayonet connection filter,
and to offer the user maximum comfort and durability. With the right filters, they provide protection
against particles and a wide variety of gases and vapors.
Facepiece made in EPDM.
Lightweight to provide great comfort.
Independent head harness system that ensures a quick and secure fit when donning it, and
quick and easy when removing it.
Panoramic polycarbonate lens that offers a wide field of view for excellent visibility.
Additionally, as an option, a lens treatment can be applied to make it scratch and solvent
resistant.
MPL bayonet connection.
Series 4000 - 20TDS - v2
Page 2
IMPORTANT NOTICE TO USERS
Series 4000
reusable half mask respirators must be used and maintained in
accordance with this instruction manual. You are responsible to understand and
follow all warnings, restrictions and other information contained in this instruction
manual before you enter a contaminated work area. Incorrect use, use of
unsuitable spare parts or bad maintenance are dangerous for health and safety and
exonerate the manufacturer from all liability. Personal protective equipments for
respiratory protection must always be used by specially trained people. The use has
to be supervised by a person perfectly aware of the limits of application and of the
applicable laws concerning those devices.
WARNINGS AND RESTRICTIONS TO USER
This full face mask does not supply oxygen (O2), and must be used in a ventilated
work environment with an oxygen volume superior or equal to 17%.
  •
Do not alter or modify this respirator.
  •
Any facial feature hindering the perfect sealing of this respirator (e.g. beards)
must be removed.
  •
If the respiratory equipment is damaged, or if the user has breathing difficulties
and/or feels ill or faint, the work area must be abandoned immediately.
  •
Do not use the filtering respirators in oxygen enriched atmospheres (>25%).
BEFORE EACH USE
Inspect your respirator before and after wearing. Don't wear, and return to your
supervisor if:
  •
Head straps are torn, cut, or have lost elasticity.
  •
Buckles or head cradle are missing, damaged or broken.
  •
Facepiece is cracked, torn, distorted, dirty, or has holes.
  •
Inhale/exhale valves are missing, torn, damaged, or not properly seated.
  •
Make sure the type of filter selected is appropriate for the specific use of the full
face mask.
  •
Filters are cracked, damaged, or not properly seated.
  •
Any other plastic part is cracked, distorted, or damaged.
MAINTENANCE
The effective life of the respirator will be influenced by the use conditions and
contaminants to which it is exposed. It is highly recommended to follow next steps
CERTIFICATION
MPL Series 4000
are:
  •
Certified according to Regulation (EU) 2016/425 relative to Personal Protective
Equipment.
  •
Certified as Category III PPE, in accordance with the harmonized standard EN
136:1998/AC:2003.
  •
CE marked.
MPL's management system is ISO 9001:2015 certified.
after every use:
1. Check if the material shows any signs of cracking, wrinkling, or aging. If so,
then discard the facepiece immediately.
2. Store the respirator, cleaned, in a sealed bag.
CLEANING AND DISINFECTION
Cleaning is recommended after each day's use or more frequently if necessary:
1. Remove the filters before proceeding with the cleaning.
2. Gently scrub the facepiece with a soft brush in a mild germicidal detergent,
rinse with clean water and air dry. Don't use solvents to wipe or clean the
facepiece as these will reduce the life of the respirator and pose a health
hazard to the user.
3. Dry the full face mask thoroughly.
REPLACEMENT PARTS
In case of cracking, wrinkling or aging, spare parts can be replaced without using
any tools: inhale/exhale valves and head harness assembly.
STORAGE
When not in use or during storage, do not expose respirator to excessive heat
(above 50ºC) or hazardous substances.
PACKAGING
Every respirator is supplied in an individual case with this instruction manual for the
user included.
MODEL
FACEPIECE
DISPLAY
4000C
EPDM
15 units per box
LIMITATIONS
Respirators may reduce but do not eliminate wearer exposure to airborne hazards
or the risk of contracting any disease or infection. Only use this respirator as part of
a comprehensive respiratory protection program. You will receive no respiratory
protection if this respirator is not properly fitted and worn. It is imperative that you
determine the size and potential hazards that may be present in the environment
before selecting appropriate respiratory protection.
CARTRIDGES & FILTERS
Series 4000
full face mask should be used with the
MPL Series B
bayonet
connection filters.
86, Carles Buïgas
08187 Santa Eulàlia de Ronçana
Barcelona - Spain