GB
Application
Can be used in conjunction with: Pressurised storage heaters,
thermally and hydraulically controlled instantaneous heaters.
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
Technical data
• Flow pressure
- min.
- recommended
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between cold and hot water
supply.
• Flow rate at 3 bar flow pressure:
- rinsing spray
- aerator
• Temperature:
- Hot water inlet
- Recommended (energy saving)
• Water connection:
• Clamping length
Note:
All GROHE single-hole mixers with pull-out sprays are
equipped with non-return valves.
3
Installation
Flush pipes thoroughly!
Prepare sink mixer
Refer to the dimensional drawing on fold-out page I.
Mount sink mixer, see fold-out page II, Fig. [1].
1. Fit O-Ring (A).
2. Insert mixer into sink. Feed the connection hoses separately
through the sink.
0.5 bar
3. Fit support plate (B), if necessary with washer (C) and
1 - 5 bar
connect nut (D) with tube (E). To do this, insert installation
max. 10 bar
tool (G) into tube (E) and turn installation tool (G) clockwise
16 bar
to fasten mixer.
(Tube may also have to be turned with an 22mm open ended
spanner.)
Note:
approx. 11 l/min
If the support plate (B) is omitted, the clamping length can be
approx. 13 l/min
increased by 15mm.
The following lever positions can also be obtained,
(max.) 80 °C
see Fig. [2].
60 °C
cold - right
hot - left
Connect sink mixer, see Figs. [1] and [3].
- Cold water connection (marked blue)
max. 60mm
- Hot water connection (marked red)
Connect the spray hose (H), see Figs. [4] to [7].
1. Feed the spray hose (H) through the spout (J), see Fig. [4].
2. Feed the spray hose (H) through the mixer body from above
and fit spout (J) so that it snaps into place, see Fig. [5].
3. Connect handspray (K) to spray hose (H) without using any
additional seals, see Fig. [6].
4. With handspray (K) in position, slide on spring (L) onto spray
hose (H) from below.
5. Screw snap coupling (M) with O-ring (M1) on the end of the
spray hose (H) and tighten by hand.
6. Pull the sleeve (M2) of the snap coupling (M) downwards
and fit to the union (N).
To ensure that the handspray (K) is correctly seated when
inserted, lug (K1) on the handspray must engage into spout
groove (J1), see Fig. [7].
= right
= left