Burner Ignition And
Auto-Reignition
This appliance is equipped for electronic auto-reignition by
means of a spark igniter located at the rear of each
burner. The burners are designed to light at any valve
rotation that admits sufficient gas flow to support a flame
and to automatically relight following a loss of flame due
to a draft or other adverse condition. This feature is
provided as a convenience and is not intended as a safety
feature.
This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician.
Specified input rates are as shown below.
JGCP430ADP
INPUT RATES - NATURAL GAS (BTU/HR)
BURNER
LOCATION
Right Front
Right Rear
Left Front
Left Rear
JGCP636ADP and JGCP648ADP
INPUT RATES - NATURAL GAS (BTU/HR)
BURNER
LOCATION
Right Front
Right Rear
Center Front
Center Rear
Left Front
Left Rear
Model JGCP648ADP includes 1300 Watt Electric
Griddle Accessory.
Hi
Lo
17K
1700
9.2K
1050
17K
1700
5K
600
Hi
Lo
17K
1700
9.2K
1050
9.2K
1050
5K
600
17K
1700
5K
600
Required Adjustments At Time
Of Installation
The installation of this appliance must conform with local
codes, or in the absence of local codes, with the latest
edition of the National Fuel Gas Code ANSI Z223.1 USA
or current CAN/CGA-B149 INSTALLATION CODE.
V
This appliance was manufactured for use with Natural
Gas. If LP gas is the fuel of choice, follow the
conversion to LP procedure found in the installation
instructions.
V
Test all external connections for gas leaks. Never test
for gas leaks with an open flame.
V
Test all electrical connections.
11