DOWNDRAFT RECIRCULATION KIT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10. Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
INSTALLATION INSTRUCTIONS
!
INTENDED FOR DOMESTIC COOKING ONLY
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING
:
a
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi-
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
Based on "Kitchen Firesafety Tips" published by NFPA.
a
!
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
6. Please read specification label on product for further
information and requirements.
Save this manual for Electrical
Inspector and Homeowner to use.
1
Model ZRC-00LF
!
INSTALLER:

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zephyr ZRC-00LF

  • Página 1 INSTALLATION INSTRUCTIONS Model ZRC-00LF DOWNDRAFT RECIRCULATION KIT READ AND SAVE THESE INSTRUCTIONS INTENDED FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR TO REDUCE THE RISK OF INJURY TO PERSONS IN THE INJURY TO PERSONS, OBSERVE THE FOLLOWING:...
  • Página 2: Plan The Installation

    INSTALLATION INSTRUCTIONS Model ZRC-00LF CONTENTS PLAN THE INSTALLATION 1 - Recirculation Box 1 - Recirculation Filter IMPORTANT - Installation Requirements 1 - Decorative Grille The blower can be installed in either of two ways: 1 - Parts Bag (containing): (1) attached to the downdraft and stabilized with 6 - #10 x .625”...
  • Página 3: Filter Replacement

    INSTALLATION INSTRUCTIONS Model ZRC-00LF INSTALL THE RECIRCULATION BOX 1. Cut opening in cabinet base. EXHAUST • Size: 14½” x 15” THROUGH • Orientation depends upon direction of exhaust. CABINET • Double-check that blower outlet and recirculation box inlet will align.
  • Página 4: Installation Instructions

    INSTALLATION INSTRUCTIONS Model ZRC-00LF...
  • Página 5 GUIDE D’INSTALLATION Modèle ZRC-00LF ENSEMBLE DE RECIRCULATION POUR HOTTE ENCASTRÉE LIRE CES DIRECTIVES ET LES CONSERVER POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT AVERTISSEMENT AFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OBSERVEZ LES CONSIGNES SUIVANTES DE MANIÈRE À OU DE BLESSURES, SUIVEZ CES DIRECTIVES : RÉDUIRE LES RISQUES DE BLESSURES CORPORELLES EN...
  • Página 6: Planification De L'INstallation

    GUIDE D’INSTALLATION Modèle ZRC-00LF PLANIFICATION DE L’INSTALLATION CONTENU 1 - Boîtier de recirculation IMPORTANT - Exigences d’installation 1 - Filtre de recirculation Il y a deux façons d’installer le ventilateur : 1 - Grille décorative (1) fixé à la hotte encastrée et stabilisé par des pieds 1 - Sac de pièces (contenant) :...
  • Página 7: Remplacement Du Filtre

    GUIDE D’INSTALLATION Modèle ZRC-00LF INSTALLATION DU BOÎTIER DE RECIRCULATION 1. Découpez une ouverture dans la base de l’armoire. • Dimensions : 36,8 cm x 38,1 cm (14½ po x 15 po) ESORTIE • L’orientation dépend de la direction de l’échappement.
  • Página 8 GUIDE D’INSTALLATION Modèle ZRC-00LF...
  • Página 9: Juego De Recirculación De Tiro Descendente

    INSTRUCCIONES DE INSTALACIÓN Modelo ZRC-00LF JUEGO DE RECIRCULACIÓN DE TIRO DESCENDENTE LEA Y CONSERVE ESTAS INSTRUCCIONES INDICADO SOLAMENTE PARA COCINAR EN CASA ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES A LAS PERSONAS EN CASO PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA DE UN INCENDIO PRODUCIDO POR GRASA EN UNA ESTUFA, OBSERVE O LESIONES CORPORALES, OBSERVE LO SIGUIENTE:...
  • Página 10: Planee La Instalación

    INSTRUCCIONES DE INSTALACIÓN Modelo ZRC-00LF CONTENIDO PLANEE LA INSTALACIÓN 1 caja de recirculación IMPORTANTE – Requisitos de la instalación 1 filtro de recirculación El ventilador se puede instalar de una de dos maneras: 1 rejilla ornamental (1) Fijo al tiro descendente y estabilizado con patas 1 bolsa de piezas (que contiene): de montaje.
  • Página 11: Reemplazo Del Filtro

    INSTRUCCIONES DE INSTALACIÓN Modelo ZRC-00LF INSTALE LA CAJA DE RECIRCULACIÓN 1. Corte la abertura en la base del gabinete. • Tamaño: 14½ x 15 pulg. (36.8 x 38.1 cm) EXTRACCIÓN • La orientación depende de la dirección de la extracción.
  • Página 12 INSTRUCCIONES DE INSTALACIÓN Modelo ZRC-00LF 99046131A...