5B MAKE ELECTRICAL CONNECTIONS
Placetheunitonaplatformortableevenwiththecutoutopening.Theplatformmustsupport200lbs.(91kg).
Connecttheflexibleconduittotheelectricaljunctionboxasfollows:
THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE:Ifresidenceleadsorgroundarealuminumconductors,seeWARNINGinsection5A,Electrical
Requirements.
Whenconnectingtoathree-conductorbranchcircuit,iflocalcodespermit:
1.
C onnectthebareovengroundcon d uc t orwiththe
crimpedneutral(white)leadtothebranchcircuit
neutral(whiteorgrayincolor),usingwirenuts.
2.
C onnecttheovenredleadtothebranchcircuitred
lead,andtheovenblackleadtothebranchcircuit
blackleadinaccordancewithlocalcodes,using
wirenuts.
3.
I nstallproperstrainreliefclamp.
4.
I nstalljunctionboxcover.
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE:Ifresidenceleadsorgroundarealuminumconductors,seeWARNINGinsection5A,Electrical
Requirements.
Whenconnectingtoafour-conductorbranchcircuit,iflocalcodespermit:
1.
C uttheneutral(white)leadfromtheclamp.Re-strip
theneutral(white)leadtoexposetheproperlength
ofconductor.
2.
A ttachtheappliancegroundinglead(greenorbare
copper)inaccordancewithlocalcodes.
3.
C onnecttheovenneutral(white)leadtothebranch
circuitneutral(whiteorgray)inaccordancewith
localcodes,usingawirenut.
4.
C onnecttheovenredleadtothebranchcircuitred
leadandtheovenblackleadtothebranchcircuit
blackleadinac c or d ancewithlocalcodes,using
wirenuts.
5.
I nstallproperstrainreliefclamp.
6.
I nstalljunctionboxcover.
InstallationInstructions
Rangeconduit
snapsintobox
6
Red
Groundand
neutralwires
(white)
Rangeconduit
snapsintobox
Red
White
Black
Branch
circuit
Alternate
knockout
Neutralbarewire
connection
Black
Branch
circuit
Ground
wires
Alternate
knockout