VGE xclear Manual Del Usuario página 6

Ocultar thumbs Ver también para xclear:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
XCLEAR AOP COMPAC T OZONE & UV-C
INSTALLATION OF THE EARTH (DRAWING 2)
EN
1. Pull the cable (2) through the strain relief (4) before fitting the synthetic strain relief (4) onto the earth
bolt (1). Position the strain relief (4) at approximately 10 cm from the eye (2) of the earth cable.
2. Place the eye (2) of the cable onto the earth bolt that is fitted to the housing.
3. Then place a toothed lock washer (3).
4. Fit the strain relief (4), creating a loop of Ø 5 cm.
5. Finally place the second toothed lock washer (5) and the lock nut (6) onto the earth bolt.
6. Once the parts have been placed onto the earth bolt in the correct sequence, they can be
tightened with a spanner or a ring spanner number 8.
INSTALLATION OF THE DEVICE (SEE DRAWING 3)
Determine where the device will be installed. The ideal location to install your device is immediately
behind the filter. See schematic representation in the front of the manual. The installation must
always take place outside of the pond. Ensure that there is always water flowing through the unit
when the lamp is on. Never install the unit in an area exposed to full sunlight. The installation must
always take place in a dry and wellventilated area. It's possible to install the device horizontal and
vertical if the water flows bottom up (see schematic representation in the front of the manual), and
a space of 30 cm must be available underneath to carry out maintenance. An area of approx. 1.5 m
must be available at the top in order to be able to replace the lamp (K) smoothly without having to
dismantle the complete device.
1. Fit the manometer (I) onto the Venturi system using Teflon tape (not included in the delivery).
Hand-tighten the manometer.
2. Glue the entire Venturi system (K) onto the inlet (N) of the device using the supplied Ø 63-50 mm
glued socket (L). The Venturi system must be mounted onto the device in a horizontal position.
The glued socket (L) has a screw thread on one side; when gluing the glued socket, ensure that
the screw thread is inserted into the inlet (N).
3. Take the hose with the non-return valve (M). Fit the short section of the hose to the bottom
side of the device on the hose (P). Place the long section of the hose onto the adapter (Z) of the
Venturi system.
4. Then mount the complete device, including the Venturi system, at the desired place between the piping.
5. Fit the unit with the supplied pipe clips (O) in a fixed position and hand-tighten the 3-part
couplings (S). Never use a wrench, tongs or other tools to tighten synthetic parts.
6. Activate the pump and check that there is flow and no leakage in the system.
7. Insert the plug of the UV-C device into a wall socket with a safety ground. Check whether the
lamp (Q) is operating via the transparent outlet (R) of the unit.
8. The quantity of ozone air in the system can be adjusted using the ball valve (J). The closer the
ball valve is positioned, the more ozone air will enter the system. The ideal position on the
manometer is between 0.4 and 0.7 bar.
6
| XCLEAR AOP COMPACT OZONE & UV-C 75W
Important read this manual carefully before proceeding
to installation and commissioning.

Publicidad

Tabla de contenido
loading

Tabla de contenido