Pump Maintenance And Replacement; Float Valve Replacement Or Adjustment - L.B.White PC-31 Instrucciones Y Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10
Evaporative Cooler

Pump Maintenance and Replacement.

(Disconnect power supply before this procedure.)
The submersible pump is mounted inside the tank to the bottom with a retention bracket. While you are cleaning
the cooler the pump may be removed and the strainer cap on the bottom of pump can be cleaned of debris. If
pump has failed and needs replacing follow these steps:
1. Remove retention bracket.
2. Remove the switch control panel from the top of cooler, by inserting a small screwdriver into the tap slots and
pop loose.
3. The pump is connected to the control via the white plastic clip. Disconnect the pump clip and feed the plastic
clip through the control box into the cooler.
4. The pump cable is connected to the cooler by twist clips that are mounted in the side of the corner between
the left pad and the front of cooler. You may have to remove that pad to get to the clips. Also there may be
cable ties holding cable to the motor mounting bracket. Remove the pump from cooler when cable is free.
5. Reinstall the new pump in reverse. Being sure to reconnect the cable in the twist ties and secure the cable
in a manner of which it stays clear of fan blade when cooler is running. Reattach the pump clip in the control
box and reinstall the control panel in its place. Be sure not to pull any other wires loose from control switches
when you have panel loose.
6. Reinstall the control panel into the cabinet making sure it is seated.

Float Valve Replacement or Adjustment:

(Disconnect power supply before this procedure.)
The float valve is mounted to the left side of cooler if you are facing the front grill. It is held in place by the
retaining nut that is visible from the outside. The rubber washer is between the nut and cabinet. The rear panel
will have to be removed to adjust the float (if the water level is too high or too low) or remove and replace a float
that has failed to shut of water supply. Note: Be sure that the PSI of the supply water is within the 50 PSI spec.
before determining the float has failed.
1. The float valve can be purchased where you purchased your cooler.
2. Remove any hose adapters attached to the float valve nipple.
3. Remove the rear panel assembly as instructed in Section 5.
4. Remove the float valve retaining nut and rubber washer. Remove float valve from cabinet.
5. Reinstall the float valve in reverse. Set the valve adjustment to around 60 degrees for best results.
Owner's Manual • Evaporative Cooler

Publicidad

Tabla de contenido
loading

Tabla de contenido