For any two separate electric animal fences, each supplied
from a separate energizer independently timed, the distance
between the wires of the two electric animal fences shall be
at least 2.5 m (8'). If this gap is to be closed, this shall be
effected by means of electrically non-conductive material or
an isolated metal barrier.
Barbed wire or razor wire shall not be electrified by an
energizer.
A non-electrified fence incorporating barbed wire or razor
wire may be used to support one or more off-set electrified
wires of an electric animal fence. The supporting devices for
the electrified wires shall be constructed so as to ensure
that these wires are positioned at a minimum distance of
150 mm (6") from the vertical plane of the non-electrified
wires. The barbed wire and razor wire shall be earthed at
regular intervals.
Follow our recommendations regarding earthing.
A distance of at least 10 m (33') shall be maintained
between the energizer earth electrode and any other
earthing system connected parts such as the power supply
7